Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future transcatheter options. Issue 12 (29th September 2020)
- Record Type:
- Journal Article
- Title:
- Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future transcatheter options. Issue 12 (29th September 2020)
- Main Title:
- Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future transcatheter options
- Authors:
- Basman, Craig
Seetharam, Karthik
Johnson, Joel
Hemli, Jonathan M.
Brinster, Derek R.
Patel, Nirav C.
Jacob Scheinerman, S.
Kliger, Chad A.
Pirelli, Luigi - Abstract:
- Abstract: Background: Valve‐in‐valve (ViV) transcatheter aortic valve replacement (TAVR) has become a valuable option in patients with bioprosthetic failure. However, potential issues with ViV TAVR may occur in patients with high‐risk anatomy for coronary obstruction and patients with baseline smaller bioprosthetic valves at risk for patient prosthesis mismatch. The purpose of this study was, therefore, to use preoperative electrocardiography‐gated, multidetector computed tomography (MDCT) in patients undergoing isolated surgical aortic valve replacement (SAVR) to (1) identify which would be high risk for coronary occlusion with ViV TAVR, and (2) predict intraoperative SAVR sizing. Methods: Among 223 patients from our institutions' database that underwent SAVR for aortic insufficiency (AI) or aortic stenosis (AS) between January 2012 and January 2020, 48 patients had MDCT imaging before surgery (AI; n = 31, AS; n = 17). Of all patients, 67% ( n = 32) were bicuspid morphology. Results: With the use of virtual valve implantation, all patients with AI and bicuspid AS had feasible anatomy for ViV TAVR, while 38% of patients with tricuspid AS were high risk for coronary obstruction. There was a strong correlation between actual valve size implanted and preoperative MDCT measurements using annulus average diameter, area, and/or perimeter. Conclusion: Preoperative MDCT in patients undergoing SAVR is a useful tool for lifetime management, particularly in patients with tricuspidAbstract: Background: Valve‐in‐valve (ViV) transcatheter aortic valve replacement (TAVR) has become a valuable option in patients with bioprosthetic failure. However, potential issues with ViV TAVR may occur in patients with high‐risk anatomy for coronary obstruction and patients with baseline smaller bioprosthetic valves at risk for patient prosthesis mismatch. The purpose of this study was, therefore, to use preoperative electrocardiography‐gated, multidetector computed tomography (MDCT) in patients undergoing isolated surgical aortic valve replacement (SAVR) to (1) identify which would be high risk for coronary occlusion with ViV TAVR, and (2) predict intraoperative SAVR sizing. Methods: Among 223 patients from our institutions' database that underwent SAVR for aortic insufficiency (AI) or aortic stenosis (AS) between January 2012 and January 2020, 48 patients had MDCT imaging before surgery (AI; n = 31, AS; n = 17). Of all patients, 67% ( n = 32) were bicuspid morphology. Results: With the use of virtual valve implantation, all patients with AI and bicuspid AS had feasible anatomy for ViV TAVR, while 38% of patients with tricuspid AS were high risk for coronary obstruction. There was a strong correlation between actual valve size implanted and preoperative MDCT measurements using annulus average diameter, area, and/or perimeter. Conclusion: Preoperative MDCT in patients undergoing SAVR is a useful tool for lifetime management, particularly in patients with tricuspid AS. Decisions for surgical management may change based on MDCT's ability to predict intraoperative SAVR size and determine which patients may be high‐risk candidates for future ViV TAVR due to coronary artery obstruction. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 35:Issue 12(2020)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 35:Issue 12(2020)
- Issue Display:
- Volume 35, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 12
- Issue Sort Value:
- 2020-0035-0012-0000
- Page Start:
- 3354
- Page End:
- 3361
- Publication Date:
- 2020-09-29
- Subjects:
- heart‐team -- lifetime management -- multidetector computed tomography -- surgical aortic valve replacement -- transcatheter aortic valve replacement -- valve‐in‐valve
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.15080 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15666.xml