A randomised crossover study to compare the user seal check and quantitative fit test between two types of duckbill N95 particulate respirator masks: The Halyard Fluidshield® N95 and the BSN Medical ProShield® N-95 particulate respirator masks. Issue 2 (March 2021)
- Record Type:
- Journal Article
- Title:
- A randomised crossover study to compare the user seal check and quantitative fit test between two types of duckbill N95 particulate respirator masks: The Halyard Fluidshield® N95 and the BSN Medical ProShield® N-95 particulate respirator masks. Issue 2 (March 2021)
- Main Title:
- A randomised crossover study to compare the user seal check and quantitative fit test between two types of duckbill N95 particulate respirator masks: The Halyard Fluidshield® N95 and the BSN Medical ProShield® N-95 particulate respirator masks
- Authors:
- Williams, Daryl L
Kave, Benjamin
Lee, Keat
Segal, Reny
Krieser, Roni B
Mezzavia, Paul M
Ng, Irene - Abstract:
- N95 particulate respirator masks are currently recommended for all healthcare workers who care for patients with suspected or confirmed coronavirus disease (COVID-19) when performing aerosol-generating procedures. The protection provided by N95 particulate respirator masks is dependent on the filter's efficiency and seal quality. In this prospective randomised crossover study, we conducted the user seal check and the quantitative fit test on two readily available duckbill models of N95 masks, the Halyard Fluidshield® N95 (Halyard, Alpharetta, GA, USA) and the BSN Medical ProShield® N-95 (BSN Medical, Mount Waverley, Victoria) particulate respirator masks. We recruited a total of 96 anaesthetic staff, of whom 26% were of South-East Asian ethnicity. We found that both types of masks provided reasonably high fit test pass rates among our participants and there was no significant difference between the two brands (77% for the Fluidshield and 65% for the ProShield, P = 0.916). Ninety-two percent of the participants could find at least one well-fitted mask among these two types of masks. We also demonstrated that the user seal check had low accuracy and low concordance (kappa coefficient of 0.16 for the Fluidshield and 0.08 for the ProShield) when compared to the quantitative fit test, and hence was not a reliable method to test seal quality.
- Is Part Of:
- Anaesthesia and intensive care. Volume 49:Issue 2(2021)
- Journal:
- Anaesthesia and intensive care
- Issue:
- Volume 49:Issue 2(2021)
- Issue Display:
- Volume 49, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 49
- Issue:
- 2
- Issue Sort Value:
- 2021-0049-0002-0000
- Page Start:
- 112
- Page End:
- 118
- Publication Date:
- 2021-03
- Subjects:
- N95 particulate respirator masks -- quantitative fit test -- user seal check
Anesthesiology -- Periodicals
Intensive Care Units -- Periodicals
617.96 - Journal URLs:
- https://journals.sagepub.com/home/aic ↗
- DOI:
- 10.1177/0310057X20974022 ↗
- Languages:
- English
- ISSNs:
- 0310-057X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15598.xml