An in vitro system to investigate IOL: Lens capsule interaction. (February 2021)
- Record Type:
- Journal Article
- Title:
- An in vitro system to investigate IOL: Lens capsule interaction. (February 2021)
- Main Title:
- An in vitro system to investigate IOL: Lens capsule interaction
- Authors:
- Jaitli, Arjun
Roy, Joyita
Mcmahan, Sara
Liao, Jun
Tang, Liping - Abstract:
- Abstract: Posterior capsule opacification (PCO) is the most common complication associated with intraocular lens (IOL) implantation. Unfortunately, current in vitro models cannot be used to assess the potential of PCO due to their failure to simulate the posterior curvature of the lens capsule (LC) and IOL, a factor known to affect PCO pathogenesis in clinic. To overcome such a challenge, a new system to study IOL: LC interaction and potentially predict PCO was developed in this effort. It is believed that the interactions between an IOL and the lens capsule may influence the extent of PCO formation. Specifically, strong adhesion force between an IOL and the LC may impede lens epithelial cell migration and proliferation and thus reduce PCO formation. To assess the adhesion force between an IOL and LC, a new in vitro model was established with simulated LC and a custom-designed micro-force tester. A method to fabricate simulated LCs was developed by imprinting IOLs onto molten gelatin to create simulated three dimensional (3D) LCs with curvature resembling the bag-like structure that collapses on the IOL post implantation. By pushing the LC mold vertically downward, while measuring the change in position of the bending bar with respect to its start position, the adhesion force between the IOLs and LCs was measured. An in vitro system that can measure the adhesion force reproducibly between an IOL and LC with a resolution of ~1 μN was established in this study. During systemAbstract: Posterior capsule opacification (PCO) is the most common complication associated with intraocular lens (IOL) implantation. Unfortunately, current in vitro models cannot be used to assess the potential of PCO due to their failure to simulate the posterior curvature of the lens capsule (LC) and IOL, a factor known to affect PCO pathogenesis in clinic. To overcome such a challenge, a new system to study IOL: LC interaction and potentially predict PCO was developed in this effort. It is believed that the interactions between an IOL and the lens capsule may influence the extent of PCO formation. Specifically, strong adhesion force between an IOL and the LC may impede lens epithelial cell migration and proliferation and thus reduce PCO formation. To assess the adhesion force between an IOL and LC, a new in vitro model was established with simulated LC and a custom-designed micro-force tester. A method to fabricate simulated LCs was developed by imprinting IOLs onto molten gelatin to create simulated three dimensional (3D) LCs with curvature resembling the bag-like structure that collapses on the IOL post implantation. By pushing the LC mold vertically downward, while measuring the change in position of the bending bar with respect to its start position, the adhesion force between the IOLs and LCs was measured. An in vitro system that can measure the adhesion force reproducibly between an IOL and LC with a resolution of ~1 μN was established in this study. During system optimization, the 10% high molecular weight gelatin produced the best LC with the highest IOL: LC adhesion force with all test lenses that were fabricated from acrylic foldable, polymethylmethacrylate (PMMA) and silicone materials. Test IOLs exerted different adhesion force with the 3D simulated LCs in the following sequence: acrylic foldable IOL > silicone IOL > PMMA IOL. These results are in good agreement with the clinical observations associated with PCO performance of IOLs made of the same materials. This novel in vitro system can provide valuable insight on the IOL: LC interplay and its relationship to clinical PCO outcomes. Highlights: An in vitro system to measure the adhesion force between IOL and lens capsule (LC) was established. Simulated LC were fabricated to mimic 3D bag like structure. A bending bar apparatus was used to measure the adhesion force. Good inverse relationship between the adhesion force and clinical PCO outcome was observed. … (more)
- Is Part Of:
- Experimental eye research. Volume 203(2021)
- Journal:
- Experimental eye research
- Issue:
- Volume 203(2021)
- Issue Display:
- Volume 203, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 203
- Issue:
- 2021
- Issue Sort Value:
- 2021-0203-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Intraocular lens -- Lens capsule -- Adhesion force -- Posterior capsule opacification -- In vitro model -- Gelatin -- 3D model
Ophthalmology -- Periodicals
Eye -- Periodicals
Œil -- Périodiques
Ophthalmology
Periodicals
Electronic journals
612.8405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00144835 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0014-4835;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.exer.2020.108430 ↗
- Languages:
- English
- ISSNs:
- 0014-4835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15566.xml