A beneficial technique for preventing the device protrusion to the aorta during percutaneous patent ductus arteriosus closure: "Balloon-assisted device releasing technique". (10th November 2019)
- Record Type:
- Journal Article
- Title:
- A beneficial technique for preventing the device protrusion to the aorta during percutaneous patent ductus arteriosus closure: "Balloon-assisted device releasing technique". (10th November 2019)
- Main Title:
- A beneficial technique for preventing the device protrusion to the aorta during percutaneous patent ductus arteriosus closure: "Balloon-assisted device releasing technique"
- Authors:
- Epçaçan, Serdar
Bulut, Mustafa Orhan
Yücel, İlker Kemal
Çelebi, Ahmet - Abstract:
- Abstract: Background: Although percutaneous closure of patent ductus arteriosus is an established safe procedure, protrusion of the device to descending aorta may occur in various degrees during these procedures, especially in small infants. The aim of our study is to evaluate the benefits of balloon-assisted device releasing technique in the era of preventing device protrusion and conditions related to protrusion. Methods: One hundred and fifty-five infants, who underwent patent ductus arteriosus closure with Amplatzer duct occluder I device between January, 2012 and December, 2018, were retrospectively analysed. Balloon-assisted device releasing technique was used in 20 cases (group 1, 12.9%), between January, 2015 and December, 2018. Procedures in which the technique had been used were compared with the remaining ones (group 2, 87.1%, n = 135) with regard to device stabilisation, aortic disc protrusion to the aorta, iatrogenic coarctation, and device embolisation. Results: There was no significant difference by means of gender, age, weight, and the ductal diameter, whereas the average mean pulmonary artery pressure was significantly higher in group 1. Device protrusion and related complications were significantly higher in group 2; thus, additional catheterisations or surgical interventions were required, while no additional intervention was required in group 1. Conclusion: The balloon-assisted device releasing technique provides a good device stabilisation and preventsAbstract: Background: Although percutaneous closure of patent ductus arteriosus is an established safe procedure, protrusion of the device to descending aorta may occur in various degrees during these procedures, especially in small infants. The aim of our study is to evaluate the benefits of balloon-assisted device releasing technique in the era of preventing device protrusion and conditions related to protrusion. Methods: One hundred and fifty-five infants, who underwent patent ductus arteriosus closure with Amplatzer duct occluder I device between January, 2012 and December, 2018, were retrospectively analysed. Balloon-assisted device releasing technique was used in 20 cases (group 1, 12.9%), between January, 2015 and December, 2018. Procedures in which the technique had been used were compared with the remaining ones (group 2, 87.1%, n = 135) with regard to device stabilisation, aortic disc protrusion to the aorta, iatrogenic coarctation, and device embolisation. Results: There was no significant difference by means of gender, age, weight, and the ductal diameter, whereas the average mean pulmonary artery pressure was significantly higher in group 1. Device protrusion and related complications were significantly higher in group 2; thus, additional catheterisations or surgical interventions were required, while no additional intervention was required in group 1. Conclusion: The balloon-assisted device releasing technique provides a good device stabilisation and prevents protrusion of the device and related complications during percutaneous patent ductus arteriosus closure in selected cases. … (more)
- Is Part Of:
- Cardiology in the young. Volume 29:Number 11(2019)
- Journal:
- Cardiology in the young
- Issue:
- Volume 29:Number 11(2019)
- Issue Display:
- Volume 29, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 29
- Issue:
- 11
- Issue Sort Value:
- 2019-0029-0011-0000
- Page Start:
- 1380
- Page End:
- 1386
- Publication Date:
- 2019-11-10
- Subjects:
- Patent ductus arteriosus closure, -- device protrusion, -- coarctation, -- embolisation, -- balloon-assisted device releasing
Pediatric cardiology -- Periodicals
618.9212 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CTY ↗
- DOI:
- 10.1017/S1047951119002269 ↗
- Languages:
- English
- ISSNs:
- 1047-9511
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital Store
- Ingest File: