Indirect visual guided fracture reduction robot based on external markers. Issue 1 (12th September 2020)
- Record Type:
- Journal Article
- Title:
- Indirect visual guided fracture reduction robot based on external markers. Issue 1 (12th September 2020)
- Main Title:
- Indirect visual guided fracture reduction robot based on external markers
- Authors:
- Fu, Zhuoxin
Sun, Hao
Dong, Xinyu
Chen, Jianwen
Rong, Hongtao
Guo, Yue
Lin, Shengxin - Abstract:
- Abstract: Background: Traditional fracture reduction surgery cannot ensure the accuracy of the reduction while consuming the physical strength of the surgeon. Although monitoring the fracture reduction process through radiography can improve the accuracy of the reduction, it will bring radiation harm to both patients and surgeons. Methods: We proposed a novel fracture reduction solution that parallel robot is used for fracture reduction surgery. The binocular camera indirectly obtains the position and posture of the fragment wrapped by the tissue by measuring the posture of the external markers. According to the clinical experience of fracture reduction, a path is designed for fracture reduction. Then using position‐based visual serving control the robot to fracture reduction surgery. The study is approved by the ethics committee of the Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, Beijing, China. Results: Ten virtual cases of fracture were used for fracture reduction experiments. The simulation and model bone experiments are designed respectively. In model bone experiments, the fragments are reduced without collision. The angulation error after the reduction of this method is 3.3° ± 1.8°, and the axial rotation error is 0.8° ± 0.3°, the transverse stagger error and the axial direction error after reduction is 2 ± 0.5 mm and 2.5 ± 1 mm. After the reduction surgery, the external fixator is used to assist the fixing, and the deformityAbstract: Background: Traditional fracture reduction surgery cannot ensure the accuracy of the reduction while consuming the physical strength of the surgeon. Although monitoring the fracture reduction process through radiography can improve the accuracy of the reduction, it will bring radiation harm to both patients and surgeons. Methods: We proposed a novel fracture reduction solution that parallel robot is used for fracture reduction surgery. The binocular camera indirectly obtains the position and posture of the fragment wrapped by the tissue by measuring the posture of the external markers. According to the clinical experience of fracture reduction, a path is designed for fracture reduction. Then using position‐based visual serving control the robot to fracture reduction surgery. The study is approved by the ethics committee of the Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, Beijing, China. Results: Ten virtual cases of fracture were used for fracture reduction experiments. The simulation and model bone experiments are designed respectively. In model bone experiments, the fragments are reduced without collision. The angulation error after the reduction of this method is 3.3° ± 1.8°, and the axial rotation error is 0.8° ± 0.3°, the transverse stagger error and the axial direction error after reduction is 2 ± 0.5 mm and 2.5 ± 1 mm. After the reduction surgery, the external fixator is used to assist the fixing, and the deformity will be completely corrected. Conclusions: The solution can perform fracture reduction surgery with certain accuracy and effectively reduce the number of radiographic uses during surgery, and the collision between fragments is avoided during surgery. … (more)
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 17:Issue 1(2021)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 17:Issue 1(2021)
- Issue Display:
- Volume 17, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2021-0017-0001-0000
- Page Start:
- 1
- Page End:
- 11
- Publication Date:
- 2020-09-12
- Subjects:
- fracture reduction -- indirect visual servo -- parallel robot -- trajectory planning
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.2162 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15575.xml