2‐Phenoxyethanol – Bestimmung von 2‐Phenoxyethanol in der Luft am Arbeitsplatz mittels Gaschromatographie nach Thermodesorption [Air Monitoring Methods in German language, 2018]. Issue 4 (19th October 2018)
- Record Type:
- Journal Article
- Title:
- 2‐Phenoxyethanol – Bestimmung von 2‐Phenoxyethanol in der Luft am Arbeitsplatz mittels Gaschromatographie nach Thermodesorption [Air Monitoring Methods in German language, 2018]. Issue 4 (19th October 2018)
- Main Title:
- 2‐Phenoxyethanol – Bestimmung von 2‐Phenoxyethanol in der Luft am Arbeitsplatz mittels Gaschromatographie nach Thermodesorption [Air Monitoring Methods in German language, 2018]
- Authors:
- Tschickardt, M.
Krämer, W.
Schmitt, R.
Hebisch, R.
Hartwig, A. - Abstract:
- Abstract: This analytical method is a validated measurement procedure for the determination of 2‐phenoxyethanol [122‐99‐6 ] in workplace air in a concentration range of one tenth up to twice the currently valid MAK value of 5, 7 mg/m 3 . With this method simultaneously airborne 2‐phenoxyethanol in the gaseous state as well as particles are collected. Sampling is performed by drawing a defined volume of air through a quartz fibre filter located in the sampling head with an adsorption tube filled with Tenax TA connected downstream using a suitable pump. The flow rate is set to 0.066 L/min with a recommended air sample volume of approx. 4 litres. The collected 2‐phenoxyethanol alcohol is thermally desorbed and then analysed by means of gas chromatography using two detectors, a FID for quantification and a MSD to recognise potential interferences. The quantitative determination is based on a calibration function obtained by means of a multi‐point calibration. The limit of quantification is 0, 095 mg/m 3 based on an air sample of approx. 4 litres.
- Is Part Of:
- MAK collection for occupational health and safety. Volume 3:Issue 4(2018)
- Journal:
- MAK collection for occupational health and safety
- Issue:
- Volume 3:Issue 4(2018)
- Issue Display:
- Volume 3, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 3
- Issue:
- 4
- Issue Sort Value:
- 2018-0003-0004-0000
- Page Start:
- 2132
- Page End:
- 2148
- Publication Date:
- 2018-10-19
- Subjects:
- 2‐Phenoxyethanol -- Arbeitsplatzmessung -- Gefahrstoffe -- Luftanalysen -- Messverfahren -- Tenax TA -- Quarzfaserfilter -- Gaschromatographie -- GC‐FID -- GC‐MSD -- Thermodesorption -- GGP‐Mini
Biological monitoring -- Periodicals
Industrial toxicology -- Periodicals
Hazardous substances -- Periodicals
615.902 - Journal URLs:
- https://onlinelibrary.wiley.com/doi/book/10.1002/3527600418 ↗
https://series.publisso.de/index.php/en/pgseries/overview/mak/dam ↗ - DOI:
- 10.1002/3527600418.am12299kskd0020 ↗
- Languages:
- English
- ISSNs:
- 2509-2383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15563.xml