Target registration error reduction for percutaneous abdominal intervention. (January 2021)
- Record Type:
- Journal Article
- Title:
- Target registration error reduction for percutaneous abdominal intervention. (January 2021)
- Main Title:
- Target registration error reduction for percutaneous abdominal intervention
- Authors:
- Bas, Mateusz
Król, Krzysztof
Spinczyk, Dominik - Abstract:
- Graphical abstract: Highlights: Spatio-temporal correspondence between the position before and during treatment of the target point was found The breathing phase selection is based on minimizing the TRE error in III-tier registration circuits. The deformation has been modeled using Elastic Body Spline. Differential Evolution methods was used to find optimal values of Elastic Body Spline parameters. The presented method works in real time. Abstract: A real-time methodology that finds spatio-temporal correspondence between the positions of the target point in the pre-treatment 3DCT image and during the procedure was proposed. It based on minimizing the target registration error in III tier registration circuits. Particle Swarm Optimization and Differential Evaluation were used to find optimal values of Elastic Body Spline parameters in the generation of abdominal deformation field. Different transformation classes have been tested: rigid, affine, Thin Plate Spline, Elastic Body Spline. The lowest TRE was obtained for the swarm optimization algorithm - differential evolution for the rigid and affine version: 3.47 and 3.73 mm, respectively.
- Is Part Of:
- Computerized medical imaging and graphics. Volume 87(2021)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 87(2021)
- Issue Display:
- Volume 87, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 87
- Issue:
- 2021
- Issue Sort Value:
- 2021-0087-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- AQUIRC Assessing Quality Using Image Registration Circuits -- CT transposed vector of scales -- CT Computed Tomography -- DE Differential Evolution -- EBS Elastic Body Spline -- Fx a collection of independent functions of the deformation field at the point x -- FEM Finite Elements Method -- FLE Fiducial Localization Error -- FRE Fiducial Registration Error -- G basis functions for each point -- I identity matrix -- PBS Position Based Simulation -- PSO Particle Swarm Optimization -- RRIGID rigid transformation -- RAFFINE affine transformation -- rX Euclidean distance from the cartesian origin -- TPS Thin Plate Spline -- Trans translation vector -- TRE Target Registration Error -- US Ultrasound -- Vi speed of a point in the feature space -- ν the Poisson coefficient -- X position in the 3D space -- x, y, z components of the position of points
Reduction of target registration error -- Breathing motion compensation -- 3rd order registration circuits -- Deformation field -- Elastic body spline
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2020.101839 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15560.xml