Continuous Monitoring of Wound Healing Using a Wearable Enzymatic Uric Acid Biosensor. Issue 8 (16th May 2018)
- Record Type:
- Journal Article
- Title:
- Continuous Monitoring of Wound Healing Using a Wearable Enzymatic Uric Acid Biosensor. Issue 8 (16th May 2018)
- Main Title:
- Continuous Monitoring of Wound Healing Using a Wearable Enzymatic Uric Acid Biosensor
- Authors:
- RoyChoudhury, Sohini
Umasankar, Yogeswaran
Jaller, Jose
Herskovitz, Ingrid
Mervis, Joshua
Darwin, Evan
Hirt, Penelope A.
Borda, Luis J.
Lev-Tov, Hadar A.
Kirsner, Robert
Bhansali, Shekhar - Abstract:
- Abstract : Wound management involves repeated clinical trips and procedures of lab tests over days. To eliminate this time lag and provide real-time monitoring of a wound's progress, we have designed an enzymatic biosensor for determining uric acid (UA) in wound fluid. Uric Acid is a biomarker, having an established correlation with wounds and their healing. This electrochemical biosensor comprises enzyme urate oxidase (uricase, UOx) entrapped in a polyvinyl alcohol based cationic polymer for enhanced stability. Results show that the use of a redox electron shuttle, ferrocene carboxylic acid (FCA), enabled electron transfer between the enzyme and the transducer. The immobilized uricase in the polymer matrix provided stable continuous measurements at body temperature for a week with minimal deviation. Detection of uric acid in wound fluid has been determined from volumes as low as 0.5–50μL. Studies from different wound samples have shown an average recovery of 107%. The sensor has been interfaced with LMP91000 potentiostat and controlled by CC2650 microcontroller on a Kapton tape-based miniaturized flexible platform.
- Is Part Of:
- Journal of the Electrochemical Society. Volume 165:Issue 8(2018)
- Journal:
- Journal of the Electrochemical Society
- Issue:
- Volume 165:Issue 8(2018)
- Issue Display:
- Volume 165, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 165
- Issue:
- 8
- Issue Sort Value:
- 2018-0165-0008-0000
- Page Start:
- B3168
- Page End:
- B3175
- Publication Date:
- 2018-05-16
- Subjects:
- electrochemical biosensor -- uricase enzyme -- Wound-care
Electrochemistry -- Periodicals
541.3705 - Journal URLs:
- https://iopscience.iop.org/journal/1945-7111?gclid=EAIaIQobChMI4Y-UmqGC7wIVFeDtCh0VQAo7EAAYASAAEgLW8_D_BwE ↗
- DOI:
- 10.1149/2.0231808jes ↗
- Languages:
- English
- ISSNs:
- 0013-4651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15551.xml