Reliability and agreement of a dynamic quadriceps incremental test for the assessment of neuromuscular function. (February 2021)
- Record Type:
- Journal Article
- Title:
- Reliability and agreement of a dynamic quadriceps incremental test for the assessment of neuromuscular function. (February 2021)
- Main Title:
- Reliability and agreement of a dynamic quadriceps incremental test for the assessment of neuromuscular function
- Authors:
- Varesco, Giorgio
Royer, Nicolas
Singh, Benjamin
Parent, Audrey
Féasson, Léonard
Lapole, Thomas
Millet, Guillaume Y
Rozand, Vianney - Abstract:
- Abstract: The quadriceps-intermittent-fatigue (QIF) test assesses knee extensors strength, endurance and performance fatigability in isometric condition. We aimed to assess reliability and agreement for this test in dynamic conditions and with the use of transcranial magnetic stimulation. On two separate sessions, 20 young adults (25 ± 4 yr, 10 women) performed stages of 100 knee extensors concentric contractions at 120°/s (60° range-of-motion) with 10% increments of the initial maximal concentric torque until exhaustion. Performance fatigability across the test was quantified as maximal isometric and concentric torque loss, and its mechanisms were investigated through the responses to transcranial magnetic and electrical stimulations. Reliability and agreement were assessed using ANOVAs, coefficients of variation (CVs) and intra-class correlation coefficients (ICCs) with 95% CI. Good inter-session reliability and high agreement were found for number of contractions [489 ± 75 vs. 503 ± 95; P = 0.20; ICC = 0.85 (0.66; 0.94); CV = 5% (3; 7)] and total work [11, 285 ± 4, 932 vs. 11, 792 ± 5838 Nm.s; P = 0.20; ICC = 0.95 (0.87; 0.98); CV = 8% (5; 11)]. Poor reliability but high agreement were observed for isometric [–33 ± 6 vs. −31 ± 7%; P = 0.13; ICC = 0.47 (0.05; 0.75); CV = 6% (4;8)] and concentric [−20 ± 11% vs. −19 ± 9%; P = 0.82; ICC = 0.26 (−0.22; 0.63); CV = 9% (6; 12)] torque loss. The dynamic QIF test represents a promising tool for neuromuscular evaluation inAbstract: The quadriceps-intermittent-fatigue (QIF) test assesses knee extensors strength, endurance and performance fatigability in isometric condition. We aimed to assess reliability and agreement for this test in dynamic conditions and with the use of transcranial magnetic stimulation. On two separate sessions, 20 young adults (25 ± 4 yr, 10 women) performed stages of 100 knee extensors concentric contractions at 120°/s (60° range-of-motion) with 10% increments of the initial maximal concentric torque until exhaustion. Performance fatigability across the test was quantified as maximal isometric and concentric torque loss, and its mechanisms were investigated through the responses to transcranial magnetic and electrical stimulations. Reliability and agreement were assessed using ANOVAs, coefficients of variation (CVs) and intra-class correlation coefficients (ICCs) with 95% CI. Good inter-session reliability and high agreement were found for number of contractions [489 ± 75 vs. 503 ± 95; P = 0.20; ICC = 0.85 (0.66; 0.94); CV = 5% (3; 7)] and total work [11, 285 ± 4, 932 vs. 11, 792 ± 5838 Nm.s; P = 0.20; ICC = 0.95 (0.87; 0.98); CV = 8% (5; 11)]. Poor reliability but high agreement were observed for isometric [–33 ± 6 vs. −31 ± 7%; P = 0.13; ICC = 0.47 (0.05; 0.75); CV = 6% (4;8)] and concentric [−20 ± 11% vs. −19 ± 9%; P = 0.82; ICC = 0.26 (−0.22; 0.63); CV = 9% (6; 12)] torque loss. The dynamic QIF test represents a promising tool for neuromuscular evaluation in isokinetic mode. … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 56(2021)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 56(2021)
- Issue Display:
- Volume 56, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 2021
- Issue Sort Value:
- 2021-0056-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Evaluation -- Fatigability -- Neuromuscular fatigue -- Isokinetic -- Transcranial magnetic stimulation
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2020.102503 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15540.xml