How not to run out of oxygen: Primary FRCA forcibly put into practice by COVID-19 to maintain patient safety. Issue 2 (April 2021)
- Record Type:
- Journal Article
- Title:
- How not to run out of oxygen: Primary FRCA forcibly put into practice by COVID-19 to maintain patient safety. Issue 2 (April 2021)
- Main Title:
- How not to run out of oxygen: Primary FRCA forcibly put into practice by COVID-19 to maintain patient safety
- Authors:
- Lake, Daniel
Henwood, Matthew
Eadie, Phil
Dagg, Kevin
Searle, Peter
Fenlon, Stephen
Iossifidis, Francoise - Abstract:
- Background: SARS-CoV-2 is currently the cause of a global pandemic, putting significant strain on healthcare systems worldwide. Reports reaching the United Kingdom, ahead of the pandemic, and previous surge planning (H1N1 influenza) highlighted that pipeline oxygen supply could be strained. Therefore, this study was created to investigate the robustness of pipeline oxygen supply at Darent Valley Hospital. Coinciding news reports of hospitals declaring major incidents, due to oxygen failure, further backed the contingency planning. Methods: The maximum sustainable flow from the vacuum insulated evaporator (VIE) was calculated, followed by a snapshot survey identifying the exact usage of oxygen (litres per minute) across the entire hospital, also highlighting areas of high demand. A flowchart protocol was created for clinicians and engineers to follow should pipeline pressure drop. Finally, a second audit, monitoring oxygen usage and pipeline pressure, throughout the surge period, was undertaken. Results: The initial survey found a usage of 412.15 L/min, which increased to 1789 L/min during the surge, with the lowest pressure recorded at 3.6 bar. The output from the VIE plant was managed through cycling of its evaporators every 12 h, to prevent pipeline freezing. Conclusions: Data and contingency planning ensured maintenance of pipeline pressure throughout a pandemic surge of 576 COVID-19 patients. It also served as the foundation of a business case that resulted in, planning,Background: SARS-CoV-2 is currently the cause of a global pandemic, putting significant strain on healthcare systems worldwide. Reports reaching the United Kingdom, ahead of the pandemic, and previous surge planning (H1N1 influenza) highlighted that pipeline oxygen supply could be strained. Therefore, this study was created to investigate the robustness of pipeline oxygen supply at Darent Valley Hospital. Coinciding news reports of hospitals declaring major incidents, due to oxygen failure, further backed the contingency planning. Methods: The maximum sustainable flow from the vacuum insulated evaporator (VIE) was calculated, followed by a snapshot survey identifying the exact usage of oxygen (litres per minute) across the entire hospital, also highlighting areas of high demand. A flowchart protocol was created for clinicians and engineers to follow should pipeline pressure drop. Finally, a second audit, monitoring oxygen usage and pipeline pressure, throughout the surge period, was undertaken. Results: The initial survey found a usage of 412.15 L/min, which increased to 1789 L/min during the surge, with the lowest pressure recorded at 3.6 bar. The output from the VIE plant was managed through cycling of its evaporators every 12 h, to prevent pipeline freezing. Conclusions: Data and contingency planning ensured maintenance of pipeline pressure throughout a pandemic surge of 576 COVID-19 patients. It also served as the foundation of a business case that resulted in, planning, approval, and installation of a second VIE plant in four weeks, ensuring readiness for further surge activity and future pandemics. … (more)
- Is Part Of:
- Journal of patient safety and risk management. Volume 26:Issue 2(2021)
- Journal:
- Journal of patient safety and risk management
- Issue:
- Volume 26:Issue 2(2021)
- Issue Display:
- Volume 26, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 26
- Issue:
- 2
- Issue Sort Value:
- 2021-0026-0002-0000
- Page Start:
- 81
- Page End:
- 88
- Publication Date:
- 2021-04
- Subjects:
- COVID-19 pandemic -- oxygen supply -- pipeline pressure -- vacuum insulated evaporator
Medical jurisprudence -- Great Britain -- Periodicals
Medical personnel -- Malpractice -- Great Britain -- Periodicals
Risk management -- Great Britain -- Periodicals - Journal URLs:
- http://journals.sagepub.com/loi/cri ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/2516043521996580 ↗
- Languages:
- English
- ISSNs:
- 2516-0435
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15538.xml