Assessing rectal temperature with a novel non-invasive sensor. (January 2021)
- Record Type:
- Journal Article
- Title:
- Assessing rectal temperature with a novel non-invasive sensor. (January 2021)
- Main Title:
- Assessing rectal temperature with a novel non-invasive sensor
- Authors:
- Tsadok, Idan
Scheinowitz, Mickey
Shpitzer, Sagi Arieh
Ketko, Itay
Epstein, Yoram
Yanovich, Ran - Abstract:
- Abstract: Athletes, soldiers, and workers who perform intense physical activities under extreme hot conditions might encounter increased physiological thermal strain. Consequently, the increase in body core temperature (Tc ) might result in heat exhaustion and heatstroke. Thus, continuously following changes in Tc is of utmost importance. Recently, the Tcore sensor (Dräger, Germany), which employs a unique dual-sensor heat flux technology, became commercially available to measure Tc, in a hospital-controlled environment. This study aimed to evaluate the possibility of using the Tcore sensor to accurately monitor rectal temperature (Tre ), reflecting Tc, under exercise-heat stress. Thirteen healthy young males completed the study protocol, consisting of 90 min of moderate exercise (walking on a treadmill - 5 km/h, 4% elevation) under controlled hot/dry and hot/wet climatic conditions (30 °C/60% rh, 34 °C/40% rh, and 40 °C/40% rh). Tcore sensors were placed on the forehead and the left wrist. Temperatures from both Tcore sensors were recorded continuously together with Tre using a rectal thermistor. The original algorithm used by the company to estimate Tre from the Tcore sensor was found to be inadequate under the study's conditions and new models for the forehead and the wrist measurements were developed. Nearly 150, 000 measurement sets (after filtering) were used to build independent MATLAB software algorithms and test their reliability according to the cross-validationAbstract: Athletes, soldiers, and workers who perform intense physical activities under extreme hot conditions might encounter increased physiological thermal strain. Consequently, the increase in body core temperature (Tc ) might result in heat exhaustion and heatstroke. Thus, continuously following changes in Tc is of utmost importance. Recently, the Tcore sensor (Dräger, Germany), which employs a unique dual-sensor heat flux technology, became commercially available to measure Tc, in a hospital-controlled environment. This study aimed to evaluate the possibility of using the Tcore sensor to accurately monitor rectal temperature (Tre ), reflecting Tc, under exercise-heat stress. Thirteen healthy young males completed the study protocol, consisting of 90 min of moderate exercise (walking on a treadmill - 5 km/h, 4% elevation) under controlled hot/dry and hot/wet climatic conditions (30 °C/60% rh, 34 °C/40% rh, and 40 °C/40% rh). Tcore sensors were placed on the forehead and the left wrist. Temperatures from both Tcore sensors were recorded continuously together with Tre using a rectal thermistor. The original algorithm used by the company to estimate Tre from the Tcore sensor was found to be inadequate under the study's conditions and new models for the forehead and the wrist measurements were developed. Nearly 150, 000 measurement sets (after filtering) were used to build independent MATLAB software algorithms and test their reliability according to the cross-validation algorithm. Bland-Altman analysis was used to compare between the results obtained by the new models to Tre . The database consisted of a large Tre range (36.5–38.9 °C). The mean errors of the models were close to zero, and the mean absolute errors were 0.20 ± 0.16 °C and 0.27 ± 0.20 °C for the forehead and wrist, respectively. 95% of the measurements from the forehead model and 86% from the wrist model were within ±0.5 °C of Tre, and 78% (forehead) and 64% (wrist) were within ±0.3 °C. Root Mean Square Deviation (RMSD) values were 0.29 °C and 0.40 °C for the forehead and wrist models, respectively. The developed models show the feasibility to use the Tcore sensor for assessing Tre under exercise-heat conditions. Furthermore, the sensor was found to be adequate for use on the wrist as well, which might be more practical for use in field conditions. Highlights: Assessing rectal temperature (Tre ) non-invasively, using the Tcore sensor positioned on the forehead and wrist. New models were developed to reflect Tre from the Tcore sensor under the study's heat-exercise conditions. Assessing Tre noninvasively was within acceptable error (±0.3 °C to ±0.5 °C) … (more)
- Is Part Of:
- Journal of thermal biology. Volume 95(2021)
- Journal:
- Journal of thermal biology
- Issue:
- Volume 95(2021)
- Issue Display:
- Volume 95, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 95
- Issue:
- 2021
- Issue Sort Value:
- 2021-0095-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- Double sensor -- Dual heat flux -- Non-invasive monitoring -- Core temperature -- Heat stress -- Occupational health
Thermobiology -- Periodicals
Temperature -- Periodicals
Biology -- Periodicals
Thermobiologie -- Périodiques
Thermobiology
Periodicals
571.46 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03064565 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jtherbio.2020.102788 ↗
- Languages:
- English
- ISSNs:
- 0306-4565
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15523.xml