Prognostic value of serial six-minute walk tests using tele-accelerometry in patients with chronic heart failure: A pre-specified sub-study of the TIM-HF-Trial. (29th August 2020)
- Record Type:
- Journal Article
- Title:
- Prognostic value of serial six-minute walk tests using tele-accelerometry in patients with chronic heart failure: A pre-specified sub-study of the TIM-HF-Trial. (29th August 2020)
- Main Title:
- Prognostic value of serial six-minute walk tests using tele-accelerometry in patients with chronic heart failure: A pre-specified sub-study of the TIM-HF-Trial
- Authors:
- Prescher, Sandra
Schoebel, Christoph
Koehler, Kerstin
Deckwart, Oliver
Wellge, Brunhilde
Honold, Marcus
Hartmann, Oliver
Winkler, Sebastian
Koehler, Friedrich - Abstract:
- Abstract: Background: The six-minute walk test (6MWT) is an established functional test assessing exercise capacity and is used to predict clinical prognosis in patients with chronic heart failure (HF). Tele-accelerometry is a novel approach to activity monitoring using telemedical data transfer and allows a Tele-6MWT to be performed in an outpatient setting. It offers patients the option of performing simple serial follow-up tests in their own home. Aims: The aim of this study was to investigate the prognostic value of serial Tele-6MWTs using tele-accelerometry in patients with HF. Design/methods: In this proof-of-concept study, 155 patients with HF completed the Tele-6MWT in an outdoor setting once per month over a period of 0.25–21 months. We analysed the differences in the number of steps over time to predict hospitalization as a result of HF or death. Results: Patients with at least one event ( n = 31) recorded a lower number of steps and a shorter distance in Tele-6MWT at baseline compared with patients who remained event-free ( n = 124) (540.1 ± 78.4 steps vs. 601.8 ± 76.7 steps, P < 0.001 respectively; 353.2 ± 82.4 m vs. 418.8 ± 95.6 m, P < 0.001). Patients ( n = 19) who performed more than one Tele-6MWT prior to a clinical event showed no significant difference in the number of steps, regardless of whether the baseline test was compared with the last Tele-6MWT before the event or with the last two tests before the event. Conclusion: Tele-6MWT has a highAbstract: Background: The six-minute walk test (6MWT) is an established functional test assessing exercise capacity and is used to predict clinical prognosis in patients with chronic heart failure (HF). Tele-accelerometry is a novel approach to activity monitoring using telemedical data transfer and allows a Tele-6MWT to be performed in an outpatient setting. It offers patients the option of performing simple serial follow-up tests in their own home. Aims: The aim of this study was to investigate the prognostic value of serial Tele-6MWTs using tele-accelerometry in patients with HF. Design/methods: In this proof-of-concept study, 155 patients with HF completed the Tele-6MWT in an outdoor setting once per month over a period of 0.25–21 months. We analysed the differences in the number of steps over time to predict hospitalization as a result of HF or death. Results: Patients with at least one event ( n = 31) recorded a lower number of steps and a shorter distance in Tele-6MWT at baseline compared with patients who remained event-free ( n = 124) (540.1 ± 78.4 steps vs. 601.8 ± 76.7 steps, P < 0.001 respectively; 353.2 ± 82.4 m vs. 418.8 ± 95.6 m, P < 0.001). Patients ( n = 19) who performed more than one Tele-6MWT prior to a clinical event showed no significant difference in the number of steps, regardless of whether the baseline test was compared with the last Tele-6MWT before the event or with the last two tests before the event. Conclusion: Tele-6MWT has a high predictive value with respect to hospitalization as a result of HF or death from any cause and the results were comparable with the prognostic impact of a conventional 6MWT. Therefore Tele-6MWT may be used as alternative test method in the home environment. However, there is no added prognostic value of repeating Tele-6MWTs on a monthly basis. … (more)
- Is Part Of:
- European journal of preventive cardiology. Volume 23(2016)Supplement 2
- Journal:
- European journal of preventive cardiology
- Issue:
- Volume 23(2016)Supplement 2
- Issue Display:
- Volume 23, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2016-0023-0002-0000
- Page Start:
- 21
- Page End:
- 26
- Publication Date:
- 2020-08-29
- Subjects:
- Six-minute walk test -- heart failure -- activity monitoring -- telemedicine -- TIM-HF -- remote patient management -- tele-accelerometry
Cardiovascular system -- Diseases -- Prevention -- Periodicals
Cardiac patients -- Rehabilitation -- Periodicals
616.12 - Journal URLs:
- https://academic.oup.com/eurjpc/issue ↗
http://www.uk.sagepub.com/home.nav ↗
http://cpr.sagepub.com/ ↗ - DOI:
- 10.1177/2047487316671438 ↗
- Languages:
- English
- ISSNs:
- 2047-4873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15511.xml