Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up. (January 2021)
- Record Type:
- Journal Article
- Title:
- Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up. (January 2021)
- Main Title:
- Prospective, multicenter study of P4HB (Phasix™) mesh for hernia repair in cohort at risk for complications: 3-Year follow-up
- Authors:
- Roth, John Scott
Anthone, Gary J.
Selzer, Don J.
Poulose, Benjamin K.
Pierce, Richard A.
Bittner, James G.
Hope, William W.
Dunn, Raymond M.
Martindale, Robert G.
Goldblatt, Matthew I.
Earle, David B.
Romanelli, John R.
Mancini, Gregory J.
Greenberg, Jacob A.
Linn, John G.
Parra-Davila, Eduardo
Sandler, Bryan J.
Deeken, Corey R.
Verbarg, Jasenka
Salluzzo, Jennifer L.
Voeller, Guy R. - Abstract:
- Abstract: Background: This study represents a prospective, multicenter, open-label study to assess the safety, performance, and outcomes of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh for primary ventral, primary incisional, or multiply-recurrent hernia in subjects at risk for complications. This study reports 3-year clinical outcomes. Materials and methods: P4HB mesh was implanted in 121 patients via retrorectus or onlay technique. Physical exam and/or quality of life surveys were completed at 1, 3, 6, 12, 18, 24, and 36 months, with 5-year (60-month) follow-up ongoing. Results: A total of n = 121 patients were implanted with P4HB mesh (n = 75 (62%) female) with a mean age of 54.7 ± 12.0 years and mean BMI of 32.2 ± 4.5 kg/m 2 (±standard deviation). Comorbidities included: obesity (78.5%), active smokers (23.1%), COPD (28.1%), diabetes mellitus (33.1%), immunosuppression (8.3%), coronary artery disease (21.5%), chronic corticosteroid use (5.0%), hypo-albuminemia (2.5%), advanced age (5.0%), and renal insufficiency (0.8%). Hernias were repaired via retrorectus (n = 45, 37.2% with myofascial release (MR) or n = 43, 35.5% without MR), onlay (n = 8, 6.6% with MR or n = 24, 19.8% without MR), or not reported (n = 1, 0.8%). 82 patients (67.8%) completed 36-month follow-up. 17 patients (17.9% ± 0.4%) experienced hernia recurrence at 3 years, with n = 9 in the retrorectus group and n = 8 in the onlay group. SSI (n = 11) occurred in 9.3% ± 0.03% of patients. Conclusions: Long-termAbstract: Background: This study represents a prospective, multicenter, open-label study to assess the safety, performance, and outcomes of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh for primary ventral, primary incisional, or multiply-recurrent hernia in subjects at risk for complications. This study reports 3-year clinical outcomes. Materials and methods: P4HB mesh was implanted in 121 patients via retrorectus or onlay technique. Physical exam and/or quality of life surveys were completed at 1, 3, 6, 12, 18, 24, and 36 months, with 5-year (60-month) follow-up ongoing. Results: A total of n = 121 patients were implanted with P4HB mesh (n = 75 (62%) female) with a mean age of 54.7 ± 12.0 years and mean BMI of 32.2 ± 4.5 kg/m 2 (±standard deviation). Comorbidities included: obesity (78.5%), active smokers (23.1%), COPD (28.1%), diabetes mellitus (33.1%), immunosuppression (8.3%), coronary artery disease (21.5%), chronic corticosteroid use (5.0%), hypo-albuminemia (2.5%), advanced age (5.0%), and renal insufficiency (0.8%). Hernias were repaired via retrorectus (n = 45, 37.2% with myofascial release (MR) or n = 43, 35.5% without MR), onlay (n = 8, 6.6% with MR or n = 24, 19.8% without MR), or not reported (n = 1, 0.8%). 82 patients (67.8%) completed 36-month follow-up. 17 patients (17.9% ± 0.4%) experienced hernia recurrence at 3 years, with n = 9 in the retrorectus group and n = 8 in the onlay group. SSI (n = 11) occurred in 9.3% ± 0.03% of patients. Conclusions: Long-term outcomes following ventral hernia repair with P4HB mesh demonstrate low recurrence rates at 3-year (36-month) postoperative time frame with no patients developing late mesh complications or requiring mesh removal. 5-year (60-month) follow-up is ongoing. Highlights: Prospective, multicenter, open-label study of safety, performance, and outcomes. Poly-4-hydroxybutyrate mesh implanted in n = 121 patients via retrorectus or onlay. 82 patients (67.8%) completed 36-month follow-up. Hernia recurrence (n = 17, 17.9% ± 0.4%) and SSI (n = 11, 9.3% ± 0.03%) at 3 years. No patients developed late mesh complications or required mesh removal. … (more)
- Is Part Of:
- Annals of medicine and surgery. Volume 61(2021)
- Journal:
- Annals of medicine and surgery
- Issue:
- Volume 61(2021)
- Issue Display:
- Volume 61, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 61
- Issue:
- 2021
- Issue Sort Value:
- 2021-0061-2021-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2021-01
- Subjects:
- Hernia repair -- Recurrence -- Infection -- Poly-4-hydroxybutyrate -- Mesh -- Seroma
Surgery -- Periodicals
Medicine -- Periodicals
General Surgery -- Periodicals
Education, Medical -- Periodicals
Periodicals
617 - Journal URLs:
- http://www.sciencedirect.com/science/journal/20490801 ↗
http://bibpurl.oclc.org/web/73795 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/20490801 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/20490801 ↗
http://www.annalsjournal.com/home ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.amsu.2020.12.002 ↗
- Languages:
- English
- ISSNs:
- 2049-0801
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15500.xml