Pros and Cons of Left Bundle Branch Pacing: A Single-Center Experience. (December 2020)
- Record Type:
- Journal Article
- Title:
- Pros and Cons of Left Bundle Branch Pacing: A Single-Center Experience. (December 2020)
- Main Title:
- Pros and Cons of Left Bundle Branch Pacing
- Authors:
- Ravi, Venkatesh
Hanifin, Jillian L.
Larsen, Timothy
Huang, Henry D.
Trohman, Richard G.
Sharma, Parikshit S. - Abstract:
- Abstract : Background: Left bundle branch pacing (LBBP) has recently emerged as a promising alternative modality for conduction system pacing. However, limited real-world data exists on the advantages and complications associated with LBBP. We analyzed the Rush conduction system pacing registry on LBBP to assess the success rates and complications associated with LBBP. Methods: All patients with an indication for permanent pacemaker or cardiac resynchronization therapy that underwent LBBP for various reasons from June 2018 to April 2020 were included in the analysis. Results: A total of 57 of 59 patients underwent successful LBBP (success rate 97%). The average follow-up duration was 6.2±5 months. The implanted devices included 38 dual-chamber pacemakers, 17 cardiac resynchronization therapy defibrillators, and 2 cardiac resynchronization therapy pacing systems. The most common reason for performing LBBP was a high His-Bundle pacing threshold (n=23) at implant. The mean LBBP capture threshold at implant was 0.62±0.21 V at 0.4 ms which remained stable during follow-up at 0.65±0.68 V at 0.4ms. In 21 patients with cardiomyopathy, there was a significant improvement in left ventricle ejection fraction from 30±11% to 42±15%. A total of 7 lead-related complications (12.3%) were noted in the follow-up period. Three patients (5.3%) required lead revision during the follow-up period. Interventricular septal perforation occurred (as late sequela) after 2 weeks in one patient.Abstract : Background: Left bundle branch pacing (LBBP) has recently emerged as a promising alternative modality for conduction system pacing. However, limited real-world data exists on the advantages and complications associated with LBBP. We analyzed the Rush conduction system pacing registry on LBBP to assess the success rates and complications associated with LBBP. Methods: All patients with an indication for permanent pacemaker or cardiac resynchronization therapy that underwent LBBP for various reasons from June 2018 to April 2020 were included in the analysis. Results: A total of 57 of 59 patients underwent successful LBBP (success rate 97%). The average follow-up duration was 6.2±5 months. The implanted devices included 38 dual-chamber pacemakers, 17 cardiac resynchronization therapy defibrillators, and 2 cardiac resynchronization therapy pacing systems. The most common reason for performing LBBP was a high His-Bundle pacing threshold (n=23) at implant. The mean LBBP capture threshold at implant was 0.62±0.21 V at 0.4 ms which remained stable during follow-up at 0.65±0.68 V at 0.4ms. In 21 patients with cardiomyopathy, there was a significant improvement in left ventricle ejection fraction from 30±11% to 42±15%. A total of 7 lead-related complications (12.3%) were noted in the follow-up period. Three patients (5.3%) required lead revision during the follow-up period. Interventricular septal perforation occurred (as late sequela) after 2 weeks in one patient. Conclusions: LBBP can be achieved with a high success rate and low capture thresholds. Left ventricular dysfunction improved significantly during follow-up. Lead-related complications were relatively common occurring in 12.3% of initially successful implants. Lead revision was required in 3 (5%) of patients. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 13:Number 12(2020)
- Journal:
- Circulation
- Issue:
- Volume 13:Number 12(2020)
- Issue Display:
- Volume 13, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 12
- Issue Sort Value:
- 2020-0013-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- cardiac conduction system disease -- cardiac resynchronization therapy -- cardiomyopathy -- complications -- defibrillator -- electrophysiology -- ventricular septum
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.120.008874 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15467.xml