Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis. Issue 1 (1st March 2014)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis. Issue 1 (1st March 2014)
- Main Title:
- Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis
- Authors:
- Raskovalova, Tatiana
Twerenbold, Raphael
Collinson, Paul O
Keller, Till
Bouvaist, Hélène
Folli, Christian
Giavarina, Davide
Lotze, Ulrich
Eggers, Kai M
Dupuy, Anne-Marie
Chenevier-Gobeaux, Camille
Meune, Christophe
Maisel, Alan
Mueller, Christian
Labarère, José - Abstract:
- Abstract: Aims: This systematic review aimed to investigate the diagnostic accuracy of combined cardiac troponin (cTn) and copeptin assessment in comparison to cTn alone for early rule-out of acute myocardial infarction (AMI). Methods: Primary studies were eligible if they evaluated diagnostic accuracy for cTn with and without copeptin in patients with symptoms suggestive of AMI. AMI was defined according to the universal definition, using detection of cTn as a marker for myocardial necrosis. Eligible studies were identified by searching electronic databases (Medline, EMBASE, Science Citation Index Expanded, CINAHL, Pascal, and Cochrane) from inception to March 2013, reviewing conference proceedings and contacting field experts and the copeptin manufacturer. Results: In 15 studies totalling 8740 patients (prevalence of AMI 16%), adding copeptin improved the sensitivity of cTn assays (from 0.87 to 0.96, p =0.003) at the expense of lower specificity (from 0.84 to 0.56, p <0.001). In 12 studies providing data for 6988 patients without ST-segment elevation, the summary sensitivity and specificity estimates were 0.95 (95% CI 0.89 to 0.98) and 0.57 (95% CI 0.49 to 0.65) for the combined assessment of cTn and copeptin. When a high-sensitivity cTnT assay was used in combination with copeptin, the summary sensitivity and specificity estimates were 0.98 (95% CI 0.96 to 1.00) and 0.50 (95% CI 0.42 to 0.58). Conclusion: Despite substantial between-study heterogeneity, this meta-analysisAbstract: Aims: This systematic review aimed to investigate the diagnostic accuracy of combined cardiac troponin (cTn) and copeptin assessment in comparison to cTn alone for early rule-out of acute myocardial infarction (AMI). Methods: Primary studies were eligible if they evaluated diagnostic accuracy for cTn with and without copeptin in patients with symptoms suggestive of AMI. AMI was defined according to the universal definition, using detection of cTn as a marker for myocardial necrosis. Eligible studies were identified by searching electronic databases (Medline, EMBASE, Science Citation Index Expanded, CINAHL, Pascal, and Cochrane) from inception to March 2013, reviewing conference proceedings and contacting field experts and the copeptin manufacturer. Results: In 15 studies totalling 8740 patients (prevalence of AMI 16%), adding copeptin improved the sensitivity of cTn assays (from 0.87 to 0.96, p =0.003) at the expense of lower specificity (from 0.84 to 0.56, p <0.001). In 12 studies providing data for 6988 patients without ST-segment elevation, the summary sensitivity and specificity estimates were 0.95 (95% CI 0.89 to 0.98) and 0.57 (95% CI 0.49 to 0.65) for the combined assessment of cTn and copeptin. When a high-sensitivity cTnT assay was used in combination with copeptin, the summary sensitivity and specificity estimates were 0.98 (95% CI 0.96 to 1.00) and 0.50 (95% CI 0.42 to 0.58). Conclusion: Despite substantial between-study heterogeneity, this meta-analysis demonstrates that copeptin significantly improves baseline cTn sensitivity. Management studies are needed to establish the effectiveness and safety of measuring copeptin in combination with high-sensitivity cTnT for early rule-out of AMI without serial testing. … (more)
- Is Part Of:
- European heart journal. Volume 3:Issue 1(2014:Mar.)
- Journal:
- European heart journal
- Issue:
- Volume 3:Issue 1(2014:Mar.)
- Issue Display:
- Volume 3, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2014-0003-0001-0000
- Page Start:
- 18
- Page End:
- 27
- Publication Date:
- 2014-03-01
- Subjects:
- copeptin -- diagnostic accuracy -- myocardial infarction -- troponin
616.1205 - Journal URLs:
- https://academic.oup.com/ehjacc/issue ↗
http://acc.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/2048872613514015 ↗
- Languages:
- English
- ISSNs:
- 2048-8726
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15454.xml