Clinical effectiveness of a Malaysian-manufactured CAPD product: A randomised trial. Issue 3 (May 2021)
- Record Type:
- Journal Article
- Title:
- Clinical effectiveness of a Malaysian-manufactured CAPD product: A randomised trial. Issue 3 (May 2021)
- Main Title:
- Clinical effectiveness of a Malaysian-manufactured CAPD product: A randomised trial
- Authors:
- Mak, Wen Yao
Leong, Chin Tho
Ong, Loke Meng
Bavanandan, Sunita
Mushahar, Lily
Goh, Bak Leong
Wong, Hin Seng
Ahmad, Ghazali
Liew, Yew Fong
Ching, Chen Hua
Liu, Wen Jiun
Rahmat, Korina
Tan, Clare Hui-Hong
Ahmad, Mohd Kamil
Hassan, Wan Hasnul Halimi Wan
Chan, Fei Sia
Harun, Zaiha
Loh, Chek Loong
Teng, Kok Seng
Tye, Yi Loon
Khan, Shahnaz Shah Firdaus
Koh, Keng-Hee
Abdullah, Rafidah
Hooi, Lai Seong - Abstract:
- Background: We compared the clinical effectiveness of a new peritoneal dialysis (PD) product with polyvinyl chloride-containing tubing (Stay Safe Link®, SSL) with the plastic-free alternative (Stay Safe®, STS) in patients on continuous ambulatory peritoneal dialysis (CAPD). Method: A multicentre, parallel, randomised, controlled, open-label, non-inferiority trial was conducted. Adult patients receiving CAPD were randomised in a 1:1 ratio to SSL or STS. The primary outcome was the rate of peritonitis after 1 year of follow-up. Results: A total of 472 subjects were randomised (SSL, n = 233; STS, n = 239). One subject in each group was excluded from the analysis as they withdrew consent before the first dialysis dose. Four hundred and seventy subjects (SSL, n = 232; STS, n = 238) were included in the modified intention-to-treat analysis. Non-inferiority between two groups was established as no significant difference was found in peritonitis rate (incident rate ratio: 0.91, 95% CI: 0.65–1.28). No significant difference was detected in weekly Kt/V ( p = 0.58) and creatinine clearance ( p = 0.55). However, the average ultrafiltration volume was significantly lower in SSL, with a mean difference of 93 ml ( p < 0.01). SSL also demonstrated a 2.57-times higher risk of device defect than STS (95% CI: 1.77–3.75). Conclusion: SSL was non-inferior in peritonitis rate compared to plastic-free STS over 1 year in patients requiring CAPD. There was no difference in the delivered dialysisBackground: We compared the clinical effectiveness of a new peritoneal dialysis (PD) product with polyvinyl chloride-containing tubing (Stay Safe Link®, SSL) with the plastic-free alternative (Stay Safe®, STS) in patients on continuous ambulatory peritoneal dialysis (CAPD). Method: A multicentre, parallel, randomised, controlled, open-label, non-inferiority trial was conducted. Adult patients receiving CAPD were randomised in a 1:1 ratio to SSL or STS. The primary outcome was the rate of peritonitis after 1 year of follow-up. Results: A total of 472 subjects were randomised (SSL, n = 233; STS, n = 239). One subject in each group was excluded from the analysis as they withdrew consent before the first dialysis dose. Four hundred and seventy subjects (SSL, n = 232; STS, n = 238) were included in the modified intention-to-treat analysis. Non-inferiority between two groups was established as no significant difference was found in peritonitis rate (incident rate ratio: 0.91, 95% CI: 0.65–1.28). No significant difference was detected in weekly Kt/V ( p = 0.58) and creatinine clearance ( p = 0.55). However, the average ultrafiltration volume was significantly lower in SSL, with a mean difference of 93 ml ( p < 0.01). SSL also demonstrated a 2.57-times higher risk of device defect than STS (95% CI: 1.77–3.75). Conclusion: SSL was non-inferior in peritonitis rate compared to plastic-free STS over 1 year in patients requiring CAPD. There was no difference in the delivered dialysis dose, but there was a higher rate of device defects with SSL. … (more)
- Is Part Of:
- Peritoneal dialysis international. Volume 41:Issue 3(2021)
- Journal:
- Peritoneal dialysis international
- Issue:
- Volume 41:Issue 3(2021)
- Issue Display:
- Volume 41, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2021-0041-0003-0000
- Page Start:
- 273
- Page End:
- 283
- Publication Date:
- 2021-05
- Subjects:
- Creatinine clearance -- device defect -- Kt/V -- peritoneal dialysis -- peritonitis -- plasticiser -- ultrafiltration rate
Peritoneal dialysis -- Periodicals
Continuous ambulatory peritoneal dialysis -- Periodicals
617.461059 - Journal URLs:
- http://www.pdiconnect.com/ ↗
https://journals.sagepub.com/home/ptd ↗ - DOI:
- 10.1177/0896860821993954 ↗
- Languages:
- English
- ISSNs:
- 0896-8608
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15433.xml