Price of High-Throughput 25-Hydroxyvitamin D Immunoassays: Frequency of Inaccurate Results. (15th October 2019)
- Record Type:
- Journal Article
- Title:
- Price of High-Throughput 25-Hydroxyvitamin D Immunoassays: Frequency of Inaccurate Results. (15th October 2019)
- Main Title:
- Price of High-Throughput 25-Hydroxyvitamin D Immunoassays: Frequency of Inaccurate Results
- Authors:
- Tolan, Nicole V
Yoon, Edward J
Brady, Ashley R
Horowitz, Gary L - Abstract:
- Abstract: Background: With a 10-year sustained increase in 25-hydroxyvitamin D [25(OH)D] testing, laboratories have swapped their LC-MS/MS methods for high-throughput automated immunoassays. Although it is generally well-known that immunoassays have poor recoveries for 25-hydroxyvitamin D2 [25(OH)D2], the frequency and extent to which this impacts total 25(OH)D have not been previously demonstrated. We evaluated 3 automated immunoassays against the first FDA-cleared CDC/NIST-traceable LC-MS/MS method. Methods: Method comparison was performed for the Siemens ADVIA Centaur, Roche Elecsys Cobas, and Abbott Architect 25(OH)D immunoassay methods in real patient samples (n = 105). We calculated the mean bias in samples containing >20 ng/mL 25(OH)D2 and estimated the percent 25(OH)D2 cross-reactivities. We determined the prevalence of appreciable concentrations of 25(OH)D2 in our patient population through random sampling (n = 120) and projected the frequency of inaccurate 25(OH)D immunoassay results. Results: Linear regression for 25(OH)D was y = 1.09x − 4.44 (Centaur), y = 0.84 + 0.43 (Cobas), and y = 0.83x − 0.48 (Architect). The mean biases of 25(OH)D concentrations were 5.6 (11.0) ng/mL (Centaur), −17.5 (7.2) ng/mL (Cobas), and −20.3 (9.8) ng/mL (Architect) in samples containing >20 ng/mL 25(OH)D2. The observed percent cross-reactivities for 25(OH)D2 were 115% (Centaur), 52% (Cobas), and 44% (Architect). We estimate that 8% of our population has >20 ng/mL 25(OH)D2, therebyAbstract: Background: With a 10-year sustained increase in 25-hydroxyvitamin D [25(OH)D] testing, laboratories have swapped their LC-MS/MS methods for high-throughput automated immunoassays. Although it is generally well-known that immunoassays have poor recoveries for 25-hydroxyvitamin D2 [25(OH)D2], the frequency and extent to which this impacts total 25(OH)D have not been previously demonstrated. We evaluated 3 automated immunoassays against the first FDA-cleared CDC/NIST-traceable LC-MS/MS method. Methods: Method comparison was performed for the Siemens ADVIA Centaur, Roche Elecsys Cobas, and Abbott Architect 25(OH)D immunoassay methods in real patient samples (n = 105). We calculated the mean bias in samples containing >20 ng/mL 25(OH)D2 and estimated the percent 25(OH)D2 cross-reactivities. We determined the prevalence of appreciable concentrations of 25(OH)D2 in our patient population through random sampling (n = 120) and projected the frequency of inaccurate 25(OH)D immunoassay results. Results: Linear regression for 25(OH)D was y = 1.09x − 4.44 (Centaur), y = 0.84 + 0.43 (Cobas), and y = 0.83x − 0.48 (Architect). The mean biases of 25(OH)D concentrations were 5.6 (11.0) ng/mL (Centaur), −17.5 (7.2) ng/mL (Cobas), and −20.3 (9.8) ng/mL (Architect) in samples containing >20 ng/mL 25(OH)D2. The observed percent cross-reactivities for 25(OH)D2 were 115% (Centaur), 52% (Cobas), and 44% (Architect). We estimate that 8% of our population has >20 ng/mL 25(OH)D2, thereby compromising the accuracy of 25(OH)D results in >3000 samples annually. Conclusions: We demonstrate that immunoassay manufacturer package inserts indicate much better recoveries of 25(OH)D2 than what is observed in unadulterated real patient samples. We estimate the frequency of inaccurate total 25(OH)D determination by these immunoassay methods to be largely dependent on the concentration of 25(OH)D2 in each sample. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 2:Number 6(2018)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 2:Number 6(2018)
- Issue Display:
- Volume 2, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 2
- Issue:
- 6
- Issue Sort Value:
- 2018-0002-0006-0000
- Page Start:
- 868
- Page End:
- 879
- Publication Date:
- 2019-10-15
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2017.024323 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15434.xml