High-Throughput LC-MS/MS Method for Determination of the Alcohol Use Biomarker Phosphatidylethanol in Clinical Samples by Use of a Simple Automated Extraction Procedure—Preanalytical and Analytical Conditions. (15th October 2019)
- Record Type:
- Journal Article
- Title:
- High-Throughput LC-MS/MS Method for Determination of the Alcohol Use Biomarker Phosphatidylethanol in Clinical Samples by Use of a Simple Automated Extraction Procedure—Preanalytical and Analytical Conditions. (15th October 2019)
- Main Title:
- High-Throughput LC-MS/MS Method for Determination of the Alcohol Use Biomarker Phosphatidylethanol in Clinical Samples by Use of a Simple Automated Extraction Procedure—Preanalytical and Analytical Conditions
- Authors:
- Isaksson, Anders
Walther, Lisa
Hansson, Therese
Andersson, Anders
Stenton, Joanna
Blomgren, Anders - Abstract:
- Abstract: Background: Phosphatidylethanol (PEth) is an alcohol use biomarker with higher clinical sensitivity and specificity than commonly used alcohol markers. Since its introduction as a clinical alcohol-marker in 2006, the number of samples sent to our laboratory for the determination of PEth has shown a strong annual increase. This has prompted the need to develop a cost-effective and reliable analytical procedure with high capacity. Methods: An LC-MS/MS method for the determination of PEth 16:0/18:1 with a short turnaround time (3 min) has been evaluated with respect to accuracy, sensitivity, and precision. We compared this method with a previously used HPLC method, as well as a manual and a simplified automated method for sample workup, and investigated potential causes of analytic and preanalytic errors. Results: The method shows limits of detection and quantification of 0.0075 μmol/L (5.2 ng/mL) and <0.05 μmol/L (<35 ng/mL), respectively. During a 2.1-year period, the method has shown a total CV < 8% for control samples (n = 2808) in the range of 0.10 (70) to 3.5 μmol/L (2461 ng/mL). The simplified automated method for sample preparation works equally well as the manual one. No specific and clinically significant causes of preanalytic errors were found. Conclusions: This LC-MS/MS method with automated sample workup is well suited for a clinical laboratory with LC-MS/MS experience and has the capability, proven from several years of use, to produce reliable PEthAbstract: Background: Phosphatidylethanol (PEth) is an alcohol use biomarker with higher clinical sensitivity and specificity than commonly used alcohol markers. Since its introduction as a clinical alcohol-marker in 2006, the number of samples sent to our laboratory for the determination of PEth has shown a strong annual increase. This has prompted the need to develop a cost-effective and reliable analytical procedure with high capacity. Methods: An LC-MS/MS method for the determination of PEth 16:0/18:1 with a short turnaround time (3 min) has been evaluated with respect to accuracy, sensitivity, and precision. We compared this method with a previously used HPLC method, as well as a manual and a simplified automated method for sample workup, and investigated potential causes of analytic and preanalytic errors. Results: The method shows limits of detection and quantification of 0.0075 μmol/L (5.2 ng/mL) and <0.05 μmol/L (<35 ng/mL), respectively. During a 2.1-year period, the method has shown a total CV < 8% for control samples (n = 2808) in the range of 0.10 (70) to 3.5 μmol/L (2461 ng/mL). The simplified automated method for sample preparation works equally well as the manual one. No specific and clinically significant causes of preanalytic errors were found. Conclusions: This LC-MS/MS method with automated sample workup is well suited for a clinical laboratory with LC-MS/MS experience and has the capability, proven from several years of use, to produce reliable PEth results in a high-volume laboratory (>50000 clinical samples/year). … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 2:Number 6(2018)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 2:Number 6(2018)
- Issue Display:
- Volume 2, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 2
- Issue:
- 6
- Issue Sort Value:
- 2018-0002-0006-0000
- Page Start:
- 880
- Page End:
- 892
- Publication Date:
- 2019-10-15
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2017.024828 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15434.xml