The role of 99mTc-HMPAO-labelled white blood cell scintigraphy in the diagnosis of cardiac device-related infective endocarditis. (12th October 2019)
- Record Type:
- Journal Article
- Title:
- The role of 99mTc-HMPAO-labelled white blood cell scintigraphy in the diagnosis of cardiac device-related infective endocarditis. (12th October 2019)
- Main Title:
- The role of 99mTc-HMPAO-labelled white blood cell scintigraphy in the diagnosis of cardiac device-related infective endocarditis
- Authors:
- Holcman, Katarzyna
Małecka, Barbara
Rubiś, Paweł
Ząbek, Andrzej
Szot, Wojciech
Boczar, Krzysztof
Leśniak-Sobelga, Agata
Hlawaty, Marta
Wiśniowska-Śmiałek, Sylwia
Stępień, Agnieszka
Podolec, Piotr
Kostkiewicz, Magdalena - Abstract:
- Abstract: Aims: The hybrid technique of single-photon emission tomography and computed tomography with technetium99m-hexamethylpropyleneamine oxime–labelled leucocytes (99mTc-HMPAO-SPECT/CT) is an emerging diagnostic technique in patients with cardiac device-related infective endocarditis (CDRIE). This prospective study assessed the 99mTc-HMPAO-SPECT/CT diagnostic profile and its added value to the modified Duke criteria (mDuke) in CDRIE diagnostic work-up. Methods and results: The study examined 103 consecutive patients with suspected CDRIE, who underwent 99mTc-HMPAO-SPECT/CT. Diagnostic accuracy was calculated based on a final clinical CDRIE diagnosis, including microbiology, echocardiography, and a 6-month follow-up. Subsequently, we compared the diagnostic value of the initial mDuke classification with a classification including 99mTc-HMPAO-SPECT/CT positive results as an additional major CDRIE criterion: mDuke-SPECT/CT. Overall, CDRIE was diagnosed in 31 (31%) patients, whereas 35 (34%) 99mTc-HMPAO-SPECT/CT were positive. 99mTc-HMPAO-SPECT/CT was characterized by 86% accuracy, 0.69 Cohen's kappa coefficient, 84% sensitivity, 88% specificity, 93% negative, and 74% positive predictive values. The original mDuke displayed 83% accuracy, 0.52 kappa, whereas mDuke-SPECT/CT had 88% accuracy, and 0.73 kappa. Compared with mDuke, mDuke-SPECT/CT showed significantly higher sensitivity (87% vs. 48%, P < 0.001). According to mDuke, 49.5% of patients had possible CDRIE, and afterAbstract: Aims: The hybrid technique of single-photon emission tomography and computed tomography with technetium99m-hexamethylpropyleneamine oxime–labelled leucocytes (99mTc-HMPAO-SPECT/CT) is an emerging diagnostic technique in patients with cardiac device-related infective endocarditis (CDRIE). This prospective study assessed the 99mTc-HMPAO-SPECT/CT diagnostic profile and its added value to the modified Duke criteria (mDuke) in CDRIE diagnostic work-up. Methods and results: The study examined 103 consecutive patients with suspected CDRIE, who underwent 99mTc-HMPAO-SPECT/CT. Diagnostic accuracy was calculated based on a final clinical CDRIE diagnosis, including microbiology, echocardiography, and a 6-month follow-up. Subsequently, we compared the diagnostic value of the initial mDuke classification with a classification including 99mTc-HMPAO-SPECT/CT positive results as an additional major CDRIE criterion: mDuke-SPECT/CT. Overall, CDRIE was diagnosed in 31 (31%) patients, whereas 35 (34%) 99mTc-HMPAO-SPECT/CT were positive. 99mTc-HMPAO-SPECT/CT was characterized by 86% accuracy, 0.69 Cohen's kappa coefficient, 84% sensitivity, 88% specificity, 93% negative, and 74% positive predictive values. The original mDuke displayed 83% accuracy, 0.52 kappa, whereas mDuke-SPECT/CT had 88% accuracy, and 0.73 kappa. Compared with mDuke, mDuke-SPECT/CT showed significantly higher sensitivity (87% vs. 48%, P < 0.001). According to mDuke, 49.5% of patients had possible CDRIE, and after reclassification, that figure dropped to 37%. Furthermore, having assessed the diagnosis categorization improvement following the incorporation of 99mTc-HMPAO-SPECT/CT, the net reclassification index value was found to be 31.4%. Conclusion: In patients with CDRIE, 99mTc-HMPAO-SPECT/CT provides high diagnostic accuracy, whereas a negative scan excludes CDRIE with high probability. Inclusion of 99mTc-HMPAO-SPECT/CT into mDuke diagnostic criteria yields significantly higher sensitivity and a reduction in possible CDRIE diagnoses. … (more)
- Is Part Of:
- European heart journal. Volume 21:Number 9(2020)
- Journal:
- European heart journal
- Issue:
- Volume 21:Number 9(2020)
- Issue Display:
- Volume 21, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 9
- Issue Sort Value:
- 2020-0021-0009-0000
- Page Start:
- 1022
- Page End:
- 1030
- Publication Date:
- 2019-10-12
- Subjects:
- endocarditis -- cardiac device-related infective endocarditis -- radiolabelled leucocytes -- HMPAO -- scintigraphy -- SPECT/CT
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jez257 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15436.xml