Kinetics of high-sensitivity cardiac troponin T and I differ in patients with ST-segment elevation myocardial infarction treated by primary coronary intervention. Issue 4 (1st August 2016)
- Record Type:
- Journal Article
- Title:
- Kinetics of high-sensitivity cardiac troponin T and I differ in patients with ST-segment elevation myocardial infarction treated by primary coronary intervention. Issue 4 (1st August 2016)
- Main Title:
- Kinetics of high-sensitivity cardiac troponin T and I differ in patients with ST-segment elevation myocardial infarction treated by primary coronary intervention
- Authors:
- Laugaudin, Guillaume
Kuster, Nils
Petiton, Amael
Leclercq, Florence
Gervasoni, Richard
Macia, Jean-Christophe
Cung, Thien-Tri
Dupuy, Anne-Marie
Solecki, Kamila
Lattuca, Benoit
Cade, Stéphane
Cransac, Frédéric
Cristol, Jean-Paul
Roubille, François - Abstract:
- Abstract: Purpose: Cardiac biomarkers including troponins are the cornerstone of the biological definition of acute myocardial infarction. New high-sensitivity cardiac assays determining troponin T (hs-cTnT) as well as I ((hs-cTnI) from Abbott and s-cTnI from Siemens) raise concerns because of their unclear kinetics following the peak. Aims: This study aims to compare kinetics of creatine kinases, hs-cTnT, hs-cTnI and s-cTnI in patients with ST-segment elevation myocardial infarction (STEMI) treated by percutaneous coronary intervention. Methods: We prospectively studied 106 consecutive patients admitted in our institution for STEMI and treated by percutaneous coronary intervention. We evaluated for all the patients simultaneously kinetics of creatine kinases, hs-cTnT (Roche) and two different cTnIs (hs-cTnI from Abbott and s-cTnI from Siemens). Modelling of kinetics was realized using mixed effects with cubic splines. Results: Kinetics of markers showed a first peak at 10.7h (8.0–12.0) for creatine kinases, 11.8h (10.4–13.3) for hs-cTnT (Roche); 11.8h (10.7–11.8) for hs-cTnI from Abbott and 10.2h (8.7–11.6) for s-cTnI from Siemens, respectively. This peak was followed by a nearly log linear decrease for hs-cTnI/s-cTnI and creatine kinases in contrast to hs-cTnT, which appeared with a biphasic shape curve marked by a second peak at 76.9h (69.5–82.8). The analysis of the decrease in percentage of the peak value at 77h showed that hs-cTnT follows a twice lower decrease thanAbstract: Purpose: Cardiac biomarkers including troponins are the cornerstone of the biological definition of acute myocardial infarction. New high-sensitivity cardiac assays determining troponin T (hs-cTnT) as well as I ((hs-cTnI) from Abbott and s-cTnI from Siemens) raise concerns because of their unclear kinetics following the peak. Aims: This study aims to compare kinetics of creatine kinases, hs-cTnT, hs-cTnI and s-cTnI in patients with ST-segment elevation myocardial infarction (STEMI) treated by percutaneous coronary intervention. Methods: We prospectively studied 106 consecutive patients admitted in our institution for STEMI and treated by percutaneous coronary intervention. We evaluated for all the patients simultaneously kinetics of creatine kinases, hs-cTnT (Roche) and two different cTnIs (hs-cTnI from Abbott and s-cTnI from Siemens). Modelling of kinetics was realized using mixed effects with cubic splines. Results: Kinetics of markers showed a first peak at 10.7h (8.0–12.0) for creatine kinases, 11.8h (10.4–13.3) for hs-cTnT (Roche); 11.8h (10.7–11.8) for hs-cTnI from Abbott and 10.2h (8.7–11.6) for s-cTnI from Siemens, respectively. This peak was followed by a nearly log linear decrease for hs-cTnI/s-cTnI and creatine kinases in contrast to hs-cTnT, which appeared with a biphasic shape curve marked by a second peak at 76.9h (69.5–82.8). The analysis of the decrease in percentage of the peak value at 77h showed that hs-cTnT follows a twice lower decrease than other markers. Conclusion: Kinetics of hs-cTnT, hs-cTnI and s-cTnI differ significantly with a linear decrease regarding both cTnI assays contrasting with a biphasic shape curve for hs-cTnT. This is of importance for clinical management of patients in routine settings especially in follow-up after STEMI including the suspicion of reinfarction. … (more)
- Is Part Of:
- European heart journal. Volume 5:Issue 4(2016)
- Journal:
- European heart journal
- Issue:
- Volume 5:Issue 4(2016)
- Issue Display:
- Volume 5, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 5
- Issue:
- 4
- Issue Sort Value:
- 2016-0005-0004-0000
- Page Start:
- 354
- Page End:
- 363
- Publication Date:
- 2016-08-01
- Subjects:
- Acute myocardial infarction -- percutaneous coronary intervention -- high-sensitivity troponin -- creatine kinase -- troponin I -- troponin T -- kinetics
616.1205 - Journal URLs:
- https://academic.oup.com/ehjacc/issue ↗
http://acc.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/2048872615585518 ↗
- Languages:
- English
- ISSNs:
- 2048-8726
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15426.xml