Emission characteristics of condensable particulate matter and sulfur trioxide from coal-fired power plants. (February 2021)
- Record Type:
- Journal Article
- Title:
- Emission characteristics of condensable particulate matter and sulfur trioxide from coal-fired power plants. (February 2021)
- Main Title:
- Emission characteristics of condensable particulate matter and sulfur trioxide from coal-fired power plants
- Authors:
- Yang, Fuxin
Li, Zhenghong
Liu, Hexin
Feng, Peng
Tan, Houzhang
Zhang, Sicong
Lu, Xuchao - Abstract:
- Abstract: Non-criteria air pollutants, namely, sulfur trioxide (SO3 ) and condensable particulate matter (CPM), are attracted more attention due to the non-negligible emission. In this work, the migration and emission characteristics of SO3 and CPM were investigated in two typical coal-fired power plants using the isopropanol absorption method and the dry impinger method, respectively. One of the power plants was equipped with two-stage wet flue gas desulfurization (WFGD) and the other one was self-generation power plant using Zhundong coal equipped with one-stage WFGD. The mass concentrations of SO3 and CPM were measured at the inlet and outlet of the air pollution control devices. To further understand the removal characteristics, the chemical compositions in organic and inorganic fractions of CPM were analyzed. Based on the measurement data, the emission factors of CPM and SO3 were calculated. The final emissions of SO3 range from 2.16 to 2.29 mgNm −3 and the emission factor is 0.024–0.040 kg/(t of coal). The stack emissions of filterable particulate matter all meet the ultra-low emission standard and are less than 5 mgNm −3 . However, CPM emissions all exceed 10 mgNm −3 and account for more than 85% in total particulate matter. CPM concentrations are notable and the emissions should not be ignored. In both power plants, WFGD and wet electrostatic precipitator can reduce the emission of organic fraction in CPM; while one-stage WFGD has negative effect on the mitigation ofAbstract: Non-criteria air pollutants, namely, sulfur trioxide (SO3 ) and condensable particulate matter (CPM), are attracted more attention due to the non-negligible emission. In this work, the migration and emission characteristics of SO3 and CPM were investigated in two typical coal-fired power plants using the isopropanol absorption method and the dry impinger method, respectively. One of the power plants was equipped with two-stage wet flue gas desulfurization (WFGD) and the other one was self-generation power plant using Zhundong coal equipped with one-stage WFGD. The mass concentrations of SO3 and CPM were measured at the inlet and outlet of the air pollution control devices. To further understand the removal characteristics, the chemical compositions in organic and inorganic fractions of CPM were analyzed. Based on the measurement data, the emission factors of CPM and SO3 were calculated. The final emissions of SO3 range from 2.16 to 2.29 mgNm −3 and the emission factor is 0.024–0.040 kg/(t of coal). The stack emissions of filterable particulate matter all meet the ultra-low emission standard and are less than 5 mgNm −3 . However, CPM emissions all exceed 10 mgNm −3 and account for more than 85% in total particulate matter. CPM concentrations are notable and the emissions should not be ignored. In both power plants, WFGD and wet electrostatic precipitator can reduce the emission of organic fraction in CPM; while one-stage WFGD has negative effect on the mitigation of inorganic fraction in CPM with the concentrations of water-soluble ions NH4 +, SO4 2- and Cl − increasing by 41.37%, 52.22% and 91.73%, respectively. Highlights: SO3 emissions are at a low level with the concentrations of 2.16–2.29 mgNm −3 . CPM concentrations all exceed 10 mgNm −3 and account for more than 85% in TPM. The synergistic effect of ESP, WFGD and WESP for SO3 removal is not remarkable. One-stage WFGD has negative effect on the mitigation of CPMi and FPM. … (more)
- Is Part Of:
- Journal of the Energy Institute. Volume 94(2021)
- Journal:
- Journal of the Energy Institute
- Issue:
- Volume 94(2021)
- Issue Display:
- Volume 94, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 94
- Issue:
- 2021
- Issue Sort Value:
- 2021-0094-2021-0000
- Page Start:
- 146
- Page End:
- 156
- Publication Date:
- 2021-02
- Subjects:
- Sulfur trioxide -- Condensable particulate matter -- Coal-fired power plant -- Zhundong coal -- Emission characteristic -- Chemical composition
Power (Mechanics) -- Periodicals
Power resources -- Periodicals
Fuel -- Periodicals
621.04205 - Journal URLs:
- http://www.ingentaconnect.com/content/maney/eni ↗
http://www.maney.co.uk/search?fwaction=show&fwid=630 ↗
http://www.sciencedirect.com/science/journal/17439671 ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1016/j.joei.2020.12.003 ↗
- Languages:
- English
- ISSNs:
- 1743-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15423.xml