An Automated Assay for Growth Differentiation Factor 15. (15th October 2019)
- Record Type:
- Journal Article
- Title:
- An Automated Assay for Growth Differentiation Factor 15. (15th October 2019)
- Main Title:
- An Automated Assay for Growth Differentiation Factor 15
- Authors:
- Wollert, Kai C
Kempf, Tibor
Giannitsis, Evangelos
Bertsch, Thomas
Braun, Siegmund L
Maier, Harald
Reim, Manfred
Christenson, Robert H - Abstract:
- Abstract: Background: Growth differentiation factor 15 (GDF-15) can serve as a biomarker for cardiovascular disease burden and risk. We evaluated a new, fully automated electrochemiluminescence immunoassay for measuring GDF-15. Methods: Six laboratories independently characterized the Elecsys ® GDF-15 assay (Roche Diagnostics) under routine conditions. Within-run precision (repeatability), within-laboratory precision (intermediate precision), and between-laboratory precision (reproducibility) were assessed. Plasma-serum sample correlation, reagent lot-to-lot reproducibility, and instrument comparisons were performed. The Elecsys assay was compared to a research immunoradiometric assay (IRMA) and a commercially available ELISA. GDF-15 concentrations were measured with the Elecsys assay in 739 apparently healthy individuals. Results: CVs for within-run and within-laboratory precision ranged from 0.7% to 7.7% and 1.7% to 8.6%, respectively, for samples containing 670–16039 ng/L. CVs for between-laboratory precision ranged from 7.1% to 8.9% (766–14289 ng/L). Recovery of GDF-15 was comparable for serum, Li-heparin plasma, K2 - and K3 -EDTA plasma, and citrated plasma, between 2 reagent lots, and on the cobas e 411 and cobas e 601 analyzers (Roche Diagnostics). GDF-15 concentrations in the clinically relevant range (400–3000 ng/L) measured with the Elecsys assay showed a good correlation and agreement with those measured by IRMA or ELISA. GDF-15 concentrations in apparentlyAbstract: Background: Growth differentiation factor 15 (GDF-15) can serve as a biomarker for cardiovascular disease burden and risk. We evaluated a new, fully automated electrochemiluminescence immunoassay for measuring GDF-15. Methods: Six laboratories independently characterized the Elecsys ® GDF-15 assay (Roche Diagnostics) under routine conditions. Within-run precision (repeatability), within-laboratory precision (intermediate precision), and between-laboratory precision (reproducibility) were assessed. Plasma-serum sample correlation, reagent lot-to-lot reproducibility, and instrument comparisons were performed. The Elecsys assay was compared to a research immunoradiometric assay (IRMA) and a commercially available ELISA. GDF-15 concentrations were measured with the Elecsys assay in 739 apparently healthy individuals. Results: CVs for within-run and within-laboratory precision ranged from 0.7% to 7.7% and 1.7% to 8.6%, respectively, for samples containing 670–16039 ng/L. CVs for between-laboratory precision ranged from 7.1% to 8.9% (766–14289 ng/L). Recovery of GDF-15 was comparable for serum, Li-heparin plasma, K2 - and K3 -EDTA plasma, and citrated plasma, between 2 reagent lots, and on the cobas e 411 and cobas e 601 analyzers (Roche Diagnostics). GDF-15 concentrations in the clinically relevant range (400–3000 ng/L) measured with the Elecsys assay showed a good correlation and agreement with those measured by IRMA or ELISA. GDF-15 concentrations in apparently healthy individuals increased with age but did not vary by sex. Conclusions: The Elecsys GDF-15 assay demonstrates a robust analytic performance under routine conditions and provides an automated method for measuring GDF-15 concentrations in serum and plasma. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 1:Number 5(2017)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 1:Number 5(2017)
- Issue Display:
- Volume 1, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 1
- Issue:
- 5
- Issue Sort Value:
- 2017-0001-0005-0000
- Page Start:
- 510
- Page End:
- 521
- Publication Date:
- 2019-10-15
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2016.022376 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15426.xml