A 6 Second Analytical Method for Quantitation of Tacrolimus in Whole Blood by Use of Laser Diode Thermal Desorption Tandem Mass Spectrometry. (23rd October 2019)
- Record Type:
- Journal Article
- Title:
- A 6 Second Analytical Method for Quantitation of Tacrolimus in Whole Blood by Use of Laser Diode Thermal Desorption Tandem Mass Spectrometry. (23rd October 2019)
- Main Title:
- A 6 Second Analytical Method for Quantitation of Tacrolimus in Whole Blood by Use of Laser Diode Thermal Desorption Tandem Mass Spectrometry
- Authors:
- Merrigan, Stephen D
Johnson-Davis, Kamisha L - Abstract:
- Abstract: Background: Therapeutic drug monitoring of immunosuppressive drugs is imperative for organ transplant recipients. High-performance LC-MS/MS is considered gold standard; however, immunoassays provide rapid turnaround time. New technology was developed to reduce mass spectrometry analytical run-time. The laser diode thermal desorption source coupled with tandem mass spectrometry (LDTD-MS/MS) eliminates chromatographic separation to increase analytical throughput. Methods: A rapid, 6 second, LDTD-MS/MS analytical method was developed for the quantification tacrolimus in whole blood. Whole blood samples were lysed, followed by protein precipitation and solid-phase extraction. Extracted samples with desorption solution were spotted onto a LazWell plate then dried and loaded into the LDTD source for analysis with an AB SCIEX 5500 mass spectrometer in positive multiple reaction monitoring mode. The LDTD laser profile ramps from 0% to 65% of full power over 3 s and is held at 65% for 1 s before returning to initial conditions for 2 s. Results: Data presented include tacrolimus by LDTD-MS/MS comparison to LC-MS/MS, sensitivity, imprecision, interference, linearity, and stability. Method comparison between LDTD-MS/MS and a validated in-house LC-MS/MS assay yielded the following: (LDTD-MS/MS) = 1.119 (LC-MS/MS) + 0.23 ng/mL, Sy/x = 1.26, r = 0.9871 (n = 122). The limit of quantification by LDTD-MS/MS for tacrolimus was <0.3 ng/mL and total imprecision was <10%. Conclusions:Abstract: Background: Therapeutic drug monitoring of immunosuppressive drugs is imperative for organ transplant recipients. High-performance LC-MS/MS is considered gold standard; however, immunoassays provide rapid turnaround time. New technology was developed to reduce mass spectrometry analytical run-time. The laser diode thermal desorption source coupled with tandem mass spectrometry (LDTD-MS/MS) eliminates chromatographic separation to increase analytical throughput. Methods: A rapid, 6 second, LDTD-MS/MS analytical method was developed for the quantification tacrolimus in whole blood. Whole blood samples were lysed, followed by protein precipitation and solid-phase extraction. Extracted samples with desorption solution were spotted onto a LazWell plate then dried and loaded into the LDTD source for analysis with an AB SCIEX 5500 mass spectrometer in positive multiple reaction monitoring mode. The LDTD laser profile ramps from 0% to 65% of full power over 3 s and is held at 65% for 1 s before returning to initial conditions for 2 s. Results: Data presented include tacrolimus by LDTD-MS/MS comparison to LC-MS/MS, sensitivity, imprecision, interference, linearity, and stability. Method comparison between LDTD-MS/MS and a validated in-house LC-MS/MS assay yielded the following: (LDTD-MS/MS) = 1.119 (LC-MS/MS) + 0.23 ng/mL, Sy/x = 1.26, r = 0.9871 (n = 122). The limit of quantification by LDTD-MS/MS for tacrolimus was <0.3 ng/mL and total imprecision was <10%. Conclusions: Laser diode thermal desorption tandem mass spectrometry technology can provide rapid turnaround time to result for tacrolimus. The analytical time for LDTD-MS/MS was 6 s compared to 135 s by LC-MS/MS, a >95% decrease in analytical time. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 3:Number 6(2019)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 3:Number 6(2019)
- Issue Display:
- Volume 3, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 3
- Issue:
- 6
- Issue Sort Value:
- 2019-0003-0006-0000
- Page Start:
- 965
- Page End:
- 973
- Publication Date:
- 2019-10-23
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2018.027243 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15428.xml