Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use. (1st May 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use. (1st May 2020)
- Main Title:
- Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use
- Authors:
- Budelier, Melissa M
Franks, Caroline E
Logsdon, Nicole
Jannetto, Paul J
Scott, Mitchell G
Roper, Stephen M
Farnsworth, Christopher W - Abstract:
- Abstract: Background: Fentanyl is a synthetic opioid associated with illicit drug use and overdose deaths. The SEFRIA Immunalysis (IAL) and ARK fentanyl assays are both FDA-cleared, open channel immunoassays for fentanyl detection in urine. However, limited data are available in the literature comparing these assays. The objective of this study was to perform a direct comparison of these two fentanyl immunoassays. Methods: IAL and ARK fentanyl immunoassays were performed on a Roche Cobas e602 automated chemistry analyzer. Repeatability and total imprecision were compared by diluting fentanyl into urine at concentrations above, below, and at the manufacturers' cutoffs of 1.0 ng/mL. Cross-reactivity was assessed for norfentanyl and the fentanyl analogs acetylfentanyl, acrylfentanyl, and furanylfentanyl. Concordance was assessed in 90 patient samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the gold standard. Results: Repeatability varied from 11.4%–17.8% on the IAL assay and 2.8%–5.5% on the ARK assay. Total imprecision was 18.9%–40.7% on the IAL assay and 2.9%–6.4% on the ARK assay. Both assays cross-reacted with acetylfentanyl (∼100%), acrylfentanyl (∼100%), and furanylfentanyl (∼20%), but only the ARK assay cross-reacted with norfentanyl (∼3%). An admixture of 0.5 ng/mL fentanyl and 6 ng/mL norfentanyl produced a positive result on the ARK assay. Total concordance between IAL and ARK for 90 tested patient samples was 93% (kappa = 0.85). Relative toAbstract: Background: Fentanyl is a synthetic opioid associated with illicit drug use and overdose deaths. The SEFRIA Immunalysis (IAL) and ARK fentanyl assays are both FDA-cleared, open channel immunoassays for fentanyl detection in urine. However, limited data are available in the literature comparing these assays. The objective of this study was to perform a direct comparison of these two fentanyl immunoassays. Methods: IAL and ARK fentanyl immunoassays were performed on a Roche Cobas e602 automated chemistry analyzer. Repeatability and total imprecision were compared by diluting fentanyl into urine at concentrations above, below, and at the manufacturers' cutoffs of 1.0 ng/mL. Cross-reactivity was assessed for norfentanyl and the fentanyl analogs acetylfentanyl, acrylfentanyl, and furanylfentanyl. Concordance was assessed in 90 patient samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the gold standard. Results: Repeatability varied from 11.4%–17.8% on the IAL assay and 2.8%–5.5% on the ARK assay. Total imprecision was 18.9%–40.7% on the IAL assay and 2.9%–6.4% on the ARK assay. Both assays cross-reacted with acetylfentanyl (∼100%), acrylfentanyl (∼100%), and furanylfentanyl (∼20%), but only the ARK assay cross-reacted with norfentanyl (∼3%). An admixture of 0.5 ng/mL fentanyl and 6 ng/mL norfentanyl produced a positive result on the ARK assay. Total concordance between IAL and ARK for 90 tested patient samples was 93% (kappa = 0.85). Relative to LC-MS/MS, the IAL assay had a concordance of 90% (kappa = 0.79) and the ARK assay had a concordance of 94% (kappa = 0.88). Including norfentanyl in the LC-MS/MS confirmation increased the concordance of the ARK to 96% (kappa = 0.90). Conclusions: The ARK assay recognized the metabolite norfentanyl, demonstrated superior precision, and had better concordance with LC-MS/MS compared to the IAL assay. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 5:Number 6(2020)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 5:Number 6(2020)
- Issue Display:
- Volume 5, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 5
- Issue:
- 6
- Issue Sort Value:
- 2020-0005-0006-0000
- Page Start:
- 1277
- Page End:
- 1286
- Publication Date:
- 2020-05-01
- Subjects:
- Fentanyl -- drug screen -- method comparison
Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1093/jalm/jfaa048 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15422.xml