Interlaboratory Comparison for the Determination of 24, 25-Dihydroxyvitamin D3 in Human Serum Using Liquid Chromatography with Tandem Mass Spectrometry. (22nd November 2019)
- Record Type:
- Journal Article
- Title:
- Interlaboratory Comparison for the Determination of 24, 25-Dihydroxyvitamin D3 in Human Serum Using Liquid Chromatography with Tandem Mass Spectrometry. (22nd November 2019)
- Main Title:
- Interlaboratory Comparison for the Determination of 24, 25-Dihydroxyvitamin D3 in Human Serum Using Liquid Chromatography with Tandem Mass Spectrometry
- Authors:
- Wise, Stephen A
Tai, Susan S-C
Nelson, Michael A
Burdette, Carolyn Q
Camara, Johanna E
Hoofnagle, Andrew N
Laha, Thomas J
Carter, Graham D
Jones, Julia
Williams, Emma L
Barclay, Zoe J
Jones, Glenville
Kaufmann, Martin
Binkley, Neil
Kapoor, Amita
Ziegler, Toni
Cashman, Kevin D
Dowling, Kirsten G
Sempos, Christopher T - Abstract:
- Abstract: Six laboratories associated with the Vitamin D Standardization Program (VDSP) participated in an interlaboratory comparison of LC with tandem MS (MS/MS) methods for the determination of 24, 25-dihydroxyvitamin D3 [24, 25(OH)2 D3 ] in human serum. The laboratories analyzed two different serum-based Standard Reference Materials (SRMs) intended for use in the determination of 25-hydroxyvitamin D and 30 samples from the Vitamin D External Quality Assessment Scheme (DEQAS). All laboratorymethods for 24, 25(OH)2 D3 were based on isotope dilution LC-MS/MS; three of the methods used derivatization of the vitamin D metabolites before LC-MS/MS. Laboratory results were compared to the National Institute of Standards and Technology (NIST) results, which were obtained using their newly developed candidate reference measurement procedure for 24, 25(OH)2 D3 . Laboratory results for the SRM samples varied in comparability to the NIST results, with one laboratory in excellent agreement (−1.6% mean bias), three laboratories at 10–15% mean bias, and the remaining laboratory at 36% mean bias. For the 30 DEQAS samples, the mean bias for the five laboratories ranged from 6 to 15%; however, the SD of the bias ranged from 8 to 29%. As a result of this intercomparison study, one laboratory discovered and corrected a methodcalculation error and another laboratory modified and improved their LC-MS/MS method.
- Is Part Of:
- Journal of AOAC International. Volume 100:Number 5(2017)
- Journal:
- Journal of AOAC International
- Issue:
- Volume 100:Number 5(2017)
- Issue Display:
- Volume 100, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 100
- Issue:
- 5
- Issue Sort Value:
- 2017-0100-0005-0000
- Page Start:
- 1308
- Page End:
- 1317
- Publication Date:
- 2019-11-22
- Subjects:
- Agricultural chemistry -- Periodicals
Food -- Analysis -- Periodicals
543 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jaoac/ ↗ - DOI:
- 10.5740/jaoacint.17-0183 ↗
- Languages:
- English
- ISSNs:
- 1060-3271
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15416.xml