Determination of Monensin in Bovine Tissues: A Bridging Study Comparing the Bioautographic Method (FSIS CLG-MON) with a Liquid Chromatography-Tandem Mass Spectrometry Method (OMA 2011.24). (23rd November 2019)
- Record Type:
- Journal Article
- Title:
- Determination of Monensin in Bovine Tissues: A Bridging Study Comparing the Bioautographic Method (FSIS CLG-MON) with a Liquid Chromatography-Tandem Mass Spectrometry Method (OMA 2011.24). (23rd November 2019)
- Main Title:
- Determination of Monensin in Bovine Tissues: A Bridging Study Comparing the Bioautographic Method (FSIS CLG-MON) with a Liquid Chromatography-Tandem Mass Spectrometry Method (OMA 2011.24)
- Authors:
- Mizinga, Kemmy M
Burnett, Thomas J
Brunelle, Sharon L
Wallace, Michael A
Coleman, Mark R - Abstract:
- Abstract: The U.S. Department of Agriculture, Food Safety Inspection Service regulatory method for monensin, Chemistry Laboratory Guidebook CLG-MON, is a semiquantitative bioautographic method adopted in 1991. Official Method of Analysis SM (OMA) 2011.24, a modern quantitative and confirmatory LC-tandem MS method, uses no chlorinated solvents and has several advantages, including ease of use, ready availability of reagents and materials, shorter run-time, and higher throughput than CLG-MON. Therefore, a bridging study was conducted to support the replacement of method CLG-MON with OMA 2011.24 for regulatory use. Using fortified bovine tissue samples, CLG-MON yielded accuracies of 80–120% in 44 of the 56 samples tested (one sample had no result, six samples had accuracies of >120%, and five samples had accuracies of 40–160%), but the semiquantitative nature of CLG-MON prevented assessment of precision, whereas OMA 2011.24 had accuracies of 88–110% and RSDr of 0.00–15.6%. Incurred residue results corroborated these results, demonstrating improved accuracy (83.3–114%) and good precision (RSDr of 2.6–20.5%) for OMA 2011.24 compared with CLG-MON (accuracy generally within 80–150%, with exceptions). Furthermore, χ 2 analysis revealed no statistically significant difference between the two methods. Thus, the microbiological activity of monensin correlated with the determination of monensin A in bovine tissues, and OMA 2011.24 provided improved accuracy and precision over CLG-MON.
- Is Part Of:
- Journal of AOAC International. Volume 101:Number 3(2018)
- Journal:
- Journal of AOAC International
- Issue:
- Volume 101:Number 3(2018)
- Issue Display:
- Volume 101, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 101
- Issue:
- 3
- Issue Sort Value:
- 2018-0101-0003-0000
- Page Start:
- 891
- Page End:
- 896
- Publication Date:
- 2019-11-23
- Subjects:
- Agricultural chemistry -- Periodicals
Food -- Analysis -- Periodicals
543 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jaoac/ ↗ - DOI:
- 10.5740/jaoacint.17-0203 ↗
- Languages:
- English
- ISSNs:
- 1060-3271
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15413.xml