Comparison of the psychometric properties of 3 pain scales used in the pediatric emergency department: Visual Analogue Scale, Faces Pain Scale-Revised, and Colour Analogue Scale. Issue 8 (August 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of the psychometric properties of 3 pain scales used in the pediatric emergency department: Visual Analogue Scale, Faces Pain Scale-Revised, and Colour Analogue Scale. Issue 8 (August 2018)
- Main Title:
- Comparison of the psychometric properties of 3 pain scales used in the pediatric emergency department
- Authors:
- Le May, Sylvie
Ballard, Ariane
Khadra, Christelle
Gouin, Serge
Plint, Amy C.
Villeneuve, Edith
Mâsse, Benoit
Tsze, Daniel S.
Neto, Gina
Drendel, Amy L.
Auclair, Marie-Christine
McGrath, Patrick J.
Ali, Samina - Abstract:
- Abstract : Abstract: Appropriate pain measurement relies on the use of valid, reliable tools. The aim of this study was to determine and compare the psychometric properties of 3 self-reported pain scales commonly used in the pediatric emergency department (ED). The inclusion criteria were children aged 6 to 17 years presenting to the ED with a musculoskeletal injury and self-reported pain scores ≥30 mm on the mechanical Visual Analogue Scale (VAS). Self-reported pain intensity was assessed using the mechanical VAS, Faces Pain Scale-Revised (FPS-R), and Colour Analogue Scale (CAS). Convergent validity was assessed by Pearson correlations and the Bland–Altman method; responsiveness to change was assessed using paired sample t tests and standardized mean responses; and reliability was estimated using relative and absolute indices. A total of 456 participants were included, with a mean age of 11.9 years ± 2.7 and a majority were boys (252/456, 55.3%). Correlations between each pair of scales were 0.78 (VAS/FPS-R), 0.92 (VAS/CAS), and 0.79 (CAS/FPS-R). Limits of agreement (95% confidence interval) were −3.77 to 2.33 (VAS/FPS-R), −1.74 to 1.75 (VAS/CAS), and −2.21 to 3.62 (CAS/FPS-R). Responsiveness to change was demonstrated by significant differences in mean pain scores among the scales ( P < 0.0001). Intraclass correlation coefficient and coefficient of repeatability estimates suggested acceptable reliability for the 3 scales at, respectively, 0.79 and ±2.29 (VAS), 0.82 andAbstract : Abstract: Appropriate pain measurement relies on the use of valid, reliable tools. The aim of this study was to determine and compare the psychometric properties of 3 self-reported pain scales commonly used in the pediatric emergency department (ED). The inclusion criteria were children aged 6 to 17 years presenting to the ED with a musculoskeletal injury and self-reported pain scores ≥30 mm on the mechanical Visual Analogue Scale (VAS). Self-reported pain intensity was assessed using the mechanical VAS, Faces Pain Scale-Revised (FPS-R), and Colour Analogue Scale (CAS). Convergent validity was assessed by Pearson correlations and the Bland–Altman method; responsiveness to change was assessed using paired sample t tests and standardized mean responses; and reliability was estimated using relative and absolute indices. A total of 456 participants were included, with a mean age of 11.9 years ± 2.7 and a majority were boys (252/456, 55.3%). Correlations between each pair of scales were 0.78 (VAS/FPS-R), 0.92 (VAS/CAS), and 0.79 (CAS/FPS-R). Limits of agreement (95% confidence interval) were −3.77 to 2.33 (VAS/FPS-R), −1.74 to 1.75 (VAS/CAS), and −2.21 to 3.62 (CAS/FPS-R). Responsiveness to change was demonstrated by significant differences in mean pain scores among the scales ( P < 0.0001). Intraclass correlation coefficient and coefficient of repeatability estimates suggested acceptable reliability for the 3 scales at, respectively, 0.79 and ±2.29 (VAS), 0.82 and ±2.07 (CAS), and 0.76 and ±2.82 (FPS-R). The scales demonstrated good psychometric properties for children with acute pain in the ED. The VAS and CAS showed a strong convergent validity, whereas FPS-R was not in agreement with the other scales. Abstract : Mechanical Visual Analogue Scale, Faces Pain Scale-Revised, and Colour Analogue Scale have strong responsiveness and reliability. A strong agreement was found between Visual Analogue Scale and Colour Analogue Scale. … (more)
- Is Part Of:
- Pain. Volume 159:Issue 8(2018)
- Journal:
- Pain
- Issue:
- Volume 159:Issue 8(2018)
- Issue Display:
- Volume 159, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 159
- Issue:
- 8
- Issue Sort Value:
- 2018-0159-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Pediatric pain -- VAS -- FPS-R -- CAS -- Scales agreement
Pain -- Periodicals
Douleur -- Périodiques
Anesthésie -- Périodiques
Pain
Electronic journals
Periodicals
Electronic journals
616.0472 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00006396-000000000-00000 ↗
http://www.sciencedirect.com/science/journal/03043959 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03043959 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03043959 ↗
http://journals.lww.com/pain/pages/default.aspx ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1097/j.pain.0000000000001236 ↗
- Languages:
- English
- ISSNs:
- 0304-3959
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6333.795000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15400.xml