Comparison of the colon with T1 breath-hold vs T1 free-breathing—A retrospective fetal MRI study. Issue 134 (January 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of the colon with T1 breath-hold vs T1 free-breathing—A retrospective fetal MRI study. Issue 134 (January 2021)
- Main Title:
- Comparison of the colon with T1 breath-hold vs T1 free-breathing—A retrospective fetal MRI study
- Authors:
- Dovjak, G.O.
Kanbur, I.
Prayer, F.
Brugger, P.C.
Gruber, G.M.
Weber, M.
Stuhr, F.
Ulm, B.
Kasprian, G.J.
Prayer, D. - Abstract:
- Abstract: Objectives: Fetal magnetic resonance imaging (MRI) plays an increasingly important role in the prenatal diagnosis of gastrointestinal abnormalities. During gestation, the bowel develops T1-weighted hyperintensity due to meconium formation. Currently used T1-weighted sequences are performed in maternal breath-hold (BH) technique, which may take up to 20 s. The free-breathing (FB) T1-weighted 3D radial VIBE (volumetric interpolated breath-hold examination) sequence requires no breath-hold, improving patient comfort. This study aimed to address how well the FB acquisition technique can visualize large bowel structures compared to the routinely performed breath-hold sequence. Methods: Forty-seven fetal MRI studies between 21 and 36 weeks of gestation without abdominal pathologies on prenatal MRI and ultrasound were included. All fetal scans were performed using a Philips Ingenia 1.5 T MRI. Coronal T1-weighted BH and FB sequences without fat suppression were compared. The following acquisition parameters were used (T1, FB): resolution 1.137 mm, 1.004 mm; matrix size 288 × 288, 448 × 448; FOV 328 mm, 450 mm; TR 81−132 ms, 3.47 ms; TE 4.6 ms, 1.47 ms. Due to the necessity of the breath-hold the duration of the sequence could not exceed 20 s (mean duration of the T1-weighted BH sequence 15.17 s, and mean duration of the FB sequence 26.42 s). In all examined fetuses the following structures were evaluated with respect to their visibility (0-not visible, 1-partially visible,Abstract: Objectives: Fetal magnetic resonance imaging (MRI) plays an increasingly important role in the prenatal diagnosis of gastrointestinal abnormalities. During gestation, the bowel develops T1-weighted hyperintensity due to meconium formation. Currently used T1-weighted sequences are performed in maternal breath-hold (BH) technique, which may take up to 20 s. The free-breathing (FB) T1-weighted 3D radial VIBE (volumetric interpolated breath-hold examination) sequence requires no breath-hold, improving patient comfort. This study aimed to address how well the FB acquisition technique can visualize large bowel structures compared to the routinely performed breath-hold sequence. Methods: Forty-seven fetal MRI studies between 21 and 36 weeks of gestation without abdominal pathologies on prenatal MRI and ultrasound were included. All fetal scans were performed using a Philips Ingenia 1.5 T MRI. Coronal T1-weighted BH and FB sequences without fat suppression were compared. The following acquisition parameters were used (T1, FB): resolution 1.137 mm, 1.004 mm; matrix size 288 × 288, 448 × 448; FOV 328 mm, 450 mm; TR 81−132 ms, 3.47 ms; TE 4.6 ms, 1.47 ms. Due to the necessity of the breath-hold the duration of the sequence could not exceed 20 s (mean duration of the T1-weighted BH sequence 15.17 s, and mean duration of the FB sequence 26.42 s). In all examined fetuses the following structures were evaluated with respect to their visibility (0-not visible, 1-partially visible, 2-clearly visible): rectum, sigmoid, descending, transverse and ascending colon, cecum. Furthermore, motion artifacts were assessed (0-none, 1-intermediate, 2-severe motion artifacts), and the signal intensity (SI) ratio between maternal fat and fetal rectum SI was calculated. Results: No significant differences in the visibility of sigmoid and colon between BH and FB were detected, only the cecum could be seen slightly better (in 29.8 % of cases) using BH technique. Motion artifacts were similar between BH and FB. There was a non-significant SI difference (p = 0.68) in the rectum, with a higher SI in the BH sequence. Conclusions: The FB acquisition technique compared to T1 using BH is equal regarding visibility of bowel structures and artifacts. Due to non-inferiority to the BH technique, the FB sequence is a good alternative in cases where BH cannot be performed. As the FB sequence further allows for thinner slices with a good signal, even small bowel loops may be visualized. … (more)
- Is Part Of:
- European journal of radiology. Issue 134(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 134(2021)
- Issue Display:
- Volume 134, Issue 134 (2021)
- Year:
- 2021
- Volume:
- 134
- Issue:
- 134
- Issue Sort Value:
- 2021-0134-0134-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- Fetal MRI -- MRI -- Colon -- Meconium -- Gastrointestinal -- T1 sequence
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2020.109457 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15401.xml