Retrospective respiratory motion correction in cardiac cine MRI reconstruction using adversarial autoencoder and unsupervised learning. (30th November 2020)
- Record Type:
- Journal Article
- Title:
- Retrospective respiratory motion correction in cardiac cine MRI reconstruction using adversarial autoencoder and unsupervised learning. (30th November 2020)
- Main Title:
- Retrospective respiratory motion correction in cardiac cine MRI reconstruction using adversarial autoencoder and unsupervised learning
- Authors:
- Ghodrati, Vahid
Bydder, Mark
Ali, Fadil
Gao, Chang
Prosper, Ashley
Nguyen, Kim‐Lien
Hu, Peng - Abstract:
- Abstract: The aim of this study was to develop a deep neural network for respiratory motion compensation in free‐breathing cine MRI and evaluate its performance. An adversarial autoencoder network was trained using unpaired training data from healthy volunteers and patients who underwent clinically indicated cardiac MRI examinations. A U‐net structure was used for the encoder and decoder parts of the network and the code space was regularized by an adversarial objective. The autoencoder learns the identity map for the free‐breathing motion‐corrupted images and preserves the structural content of the images, while the discriminator, which interacts with the output of the encoder, forces the encoder to remove motion artifacts. The network was first evaluated based on data that were artificially corrupted with simulated rigid motion with regard to motion‐correction accuracy and the presence of any artificially created structures. Subsequently, to demonstrate the feasibility of the proposed approach in vivo, our network was trained on respiratory motion‐corrupted images in an unpaired manner and was tested on volunteer and patient data. In the simulation study, mean structural similarity index scores for the synthesized motion‐corrupted images and motion‐corrected images were 0.76 and 0.93 (out of 1), respectively. The proposed method increased the Tenengrad focus measure of the motion‐corrupted images by 12% in the simulation study and by 7% in the in vivo study. The averageAbstract: The aim of this study was to develop a deep neural network for respiratory motion compensation in free‐breathing cine MRI and evaluate its performance. An adversarial autoencoder network was trained using unpaired training data from healthy volunteers and patients who underwent clinically indicated cardiac MRI examinations. A U‐net structure was used for the encoder and decoder parts of the network and the code space was regularized by an adversarial objective. The autoencoder learns the identity map for the free‐breathing motion‐corrupted images and preserves the structural content of the images, while the discriminator, which interacts with the output of the encoder, forces the encoder to remove motion artifacts. The network was first evaluated based on data that were artificially corrupted with simulated rigid motion with regard to motion‐correction accuracy and the presence of any artificially created structures. Subsequently, to demonstrate the feasibility of the proposed approach in vivo, our network was trained on respiratory motion‐corrupted images in an unpaired manner and was tested on volunteer and patient data. In the simulation study, mean structural similarity index scores for the synthesized motion‐corrupted images and motion‐corrected images were 0.76 and 0.93 (out of 1), respectively. The proposed method increased the Tenengrad focus measure of the motion‐corrupted images by 12% in the simulation study and by 7% in the in vivo study. The average overall subjective image quality scores for the motion‐corrupted images, motion‐corrected images and breath‐held images were 2.5, 3.5 and 4.1 (out of 5.0), respectively. Nonparametric‐paired comparisons showed that there was significant difference between the image quality scores of the motion‐corrupted and breath‐held images ( P < .05); however, after correction there was no significant difference between the image quality scores of the motion‐corrected and breath‐held images. This feasibility study demonstrates the potential of an adversarial autoencoder network for correcting respiratory motion‐related image artifacts without requiring paired data. Abstract : An adversarial autoencoder network was trained using unpaired training data from healthy volunteers and patients who underwent clinically indicated cardiac MRI examinations to remove the respiratory motion artifact from free‐breathing cine. The figure shows the performance of our proposed method (blue) in removing the respiratory artifact from free‐breathing cardiac cine scan (red). … (more)
- Is Part Of:
- NMR in biomedicine. Volume 34:Number 2(2021)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 34:Number 2(2021)
- Issue Display:
- Volume 34, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 2
- Issue Sort Value:
- 2021-0034-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-11-30
- Subjects:
- adversarial autoencoder, cardiovascular magnetic resonance, deep learning, magnetic resonance imaging, respiratory motion correction
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.4433 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15387.xml