Fluoroscopy usage in contemporary interventional electrophysiology: Insights from a European registry. Issue 1 (21st November 2020)
- Record Type:
- Journal Article
- Title:
- Fluoroscopy usage in contemporary interventional electrophysiology: Insights from a European registry. Issue 1 (21st November 2020)
- Main Title:
- Fluoroscopy usage in contemporary interventional electrophysiology: Insights from a European registry
- Authors:
- Kosiuk, Jedrzej
Fiedler, Lucas
Ernst, Sabine
Duncker, David
Pavlović, Nikola
Guarguagli, Silvia
Stegmann, Clara
Miskowiec, Dawid
Garcia, Rodrigue
Russo, Vincenzo
Yakushev, Andriy
Szegedi, Nándor
De Potter, Tom - Abstract:
- Abstract: Background: Fluoroscopy has been an essential part of every electrophysiological procedure since its inception. However, till now no clear standards regarding acceptable x‐ray exposure nor recommendation how to achieve them have been proposed. Hypothesis: Current norms and quality markers required for optimal clinical routine can be identified. Methods: Centers participating in this Europe‐wide multicenter, prospective registry were requested to provide characteristics of the center, operators, technical equipment as well as procedural settings of consecutive cases. Results: Twenty‐five centers (72% university clinics, with a mean volume of 526 ± 348 procedures yearly) from 14 European countries provided data on 1788 cases [9% diagnostic procedures (DP), 38% atrial fibrillation (AF) ablations, 44% other supraventricular (SVT) ablations, and 9% ventricular ablations (VT)] conducted by 95 operators (89% male, 41 ± 7 years old). Mean dose area product (DAP) and time was 304 ± 608 cGy*cm 2, 3.6 ± 4.8 minutes, 1937 ± 608 cGy*cm 2, 15.3 ± 15.5 minutes, 805 ± 1442 cGy*cm 2, 10.6 ± 10.7 minutes, and 1277 ± 1931 cGy*cm 2, 10.4 ± 12.3 minutes for DP, AF, SVT, and VT ablations, respectively. Seven percent of all procedures were conducted without any use of fluoroscopy. Procedures in the lower quartile of DAP were performed more frequently by female operators (OR 1.707, 95%CI 1.257‐2.318, P = .001), in higher‐volume center (OR 1.001 per one additional procedure, 95%CIAbstract: Background: Fluoroscopy has been an essential part of every electrophysiological procedure since its inception. However, till now no clear standards regarding acceptable x‐ray exposure nor recommendation how to achieve them have been proposed. Hypothesis: Current norms and quality markers required for optimal clinical routine can be identified. Methods: Centers participating in this Europe‐wide multicenter, prospective registry were requested to provide characteristics of the center, operators, technical equipment as well as procedural settings of consecutive cases. Results: Twenty‐five centers (72% university clinics, with a mean volume of 526 ± 348 procedures yearly) from 14 European countries provided data on 1788 cases [9% diagnostic procedures (DP), 38% atrial fibrillation (AF) ablations, 44% other supraventricular (SVT) ablations, and 9% ventricular ablations (VT)] conducted by 95 operators (89% male, 41 ± 7 years old). Mean dose area product (DAP) and time was 304 ± 608 cGy*cm 2, 3.6 ± 4.8 minutes, 1937 ± 608 cGy*cm 2, 15.3 ± 15.5 minutes, 805 ± 1442 cGy*cm 2, 10.6 ± 10.7 minutes, and 1277 ± 1931 cGy*cm 2, 10.4 ± 12.3 minutes for DP, AF, SVT, and VT ablations, respectively. Seven percent of all procedures were conducted without any use of fluoroscopy. Procedures in the lower quartile of DAP were performed more frequently by female operators (OR 1.707, 95%CI 1.257‐2.318, P = .001), in higher‐volume center (OR 1.001 per one additional procedure, 95%CI 1.000‐1.001, P = .002), with the use of 3D‐mapping system (OR 2.622, 95%CI 2.053‐3.347, P < .001) and monoplane x‐ray system (OR 2.945, 95%CI 2.149‐4.037, P < .001). Conclusion: Exposure to ionizing radiation varies widely in daily practice for all procedure. Significant opportunities for harmonization of exposure toward the lower range has been identified. … (more)
- Is Part Of:
- Clinical cardiology. Volume 44:Issue 1(2021)
- Journal:
- Clinical cardiology
- Issue:
- Volume 44:Issue 1(2021)
- Issue Display:
- Volume 44, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2021-0044-0001-0000
- Page Start:
- 36
- Page End:
- 42
- Publication Date:
- 2020-11-21
- Subjects:
- electrophysiology -- fluoroscopy -- radiation -- x‐ray -- zero‐fluoroscopy
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.23411 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15391.xml