Hemodialysis patients with less extracellular water overload and smaller cardiac atrial chamber sizes are at greater risk of a fall in blood pressure during dialysis. Issue 1 (13th April 2020)
- Record Type:
- Journal Article
- Title:
- Hemodialysis patients with less extracellular water overload and smaller cardiac atrial chamber sizes are at greater risk of a fall in blood pressure during dialysis. Issue 1 (13th April 2020)
- Main Title:
- Hemodialysis patients with less extracellular water overload and smaller cardiac atrial chamber sizes are at greater risk of a fall in blood pressure during dialysis
- Authors:
- Yoowannakul, Suree
Vongsanim, Surachet
Kotecha, Tushar
Fontana, Marianna
Davenport, Andrew - Abstract:
- Abstract: Intradialytic hypotension is the most common complication of hemodialysis (HD) treatments. Excessive ultrafiltration results in reduced cardiac preload. We aimed to determine whether a fall in systolic blood pressure during HD was greater in patients starting HD with (a) less overhydration measured by extracellular water (ECW) and (b) lower cardiac preload by cardiac magnetic resonance imaging (MRI). Pre‐HD measurements of ECW and total body water (TBW) were performed using multifrequency bioimpedance (MFBIA). Cardiac chamber sizes and functions were determined by MRI. Twenty‐six patients, 18 males (69.2%), 11 (42.3%) with diabetes, mean age 63.9 ± 15.9 years were studied. Systolic blood pressure (SBP) fell in 15 (57.7%) patients, and either did not change or increased in 9. There was no difference in demographics between groups. Patients with a fall in SBP had lower pre‐HD ECW/TBW (0.400 ± 0.018 vs 0.418 ± 0.021), indexed right ventricular end‐diastolic volume (81.2 ± 37.6 vs 100.8 ± 33.7 mL/m 2 ), and indexed left atrial size (13.7 ± 3.9 vs 18.3 ± 5.0 mL/m 2 ), all P < .05, respectively. There were univariate correlations between the change in SBP and pre‐HD ECW/TBW for the trunk ( r = .50, P = .009) and indexed left atrial volume ( r = .54, P = .005). A fall in blood pressure occurred more commonly in patients starting HD with lower overhydration as measured by bioimpedance, and those with smaller cardiac chamber sizes. Patients with the lowest ECW/TBW andAbstract: Intradialytic hypotension is the most common complication of hemodialysis (HD) treatments. Excessive ultrafiltration results in reduced cardiac preload. We aimed to determine whether a fall in systolic blood pressure during HD was greater in patients starting HD with (a) less overhydration measured by extracellular water (ECW) and (b) lower cardiac preload by cardiac magnetic resonance imaging (MRI). Pre‐HD measurements of ECW and total body water (TBW) were performed using multifrequency bioimpedance (MFBIA). Cardiac chamber sizes and functions were determined by MRI. Twenty‐six patients, 18 males (69.2%), 11 (42.3%) with diabetes, mean age 63.9 ± 15.9 years were studied. Systolic blood pressure (SBP) fell in 15 (57.7%) patients, and either did not change or increased in 9. There was no difference in demographics between groups. Patients with a fall in SBP had lower pre‐HD ECW/TBW (0.400 ± 0.018 vs 0.418 ± 0.021), indexed right ventricular end‐diastolic volume (81.2 ± 37.6 vs 100.8 ± 33.7 mL/m 2 ), and indexed left atrial size (13.7 ± 3.9 vs 18.3 ± 5.0 mL/m 2 ), all P < .05, respectively. There were univariate correlations between the change in SBP and pre‐HD ECW/TBW for the trunk ( r = .50, P = .009) and indexed left atrial volume ( r = .54, P = .005). A fall in blood pressure occurred more commonly in patients starting HD with lower overhydration as measured by bioimpedance, and those with smaller cardiac chamber sizes. Patients with the lowest ECW/TBW and smallest cardiac chamber sizes had the greatest falls in SBP. This study reinforces the importance of determining physiological target weights and avoiding inappropriately low target weights for HD patients. … (more)
- Is Part Of:
- Therapeutic apheresis and dialysis. Volume 25:Issue 1(2021)
- Journal:
- Therapeutic apheresis and dialysis
- Issue:
- Volume 25:Issue 1(2021)
- Issue Display:
- Volume 25, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2021-0025-0001-0000
- Page Start:
- 16
- Page End:
- 23
- Publication Date:
- 2020-04-13
- Subjects:
- bioimpedance -- cardiac magnetic resonance imaging -- extracellular water -- hemodialysis -- hypotension
Hemapheresis -- Periodicals
Dialysis -- Periodicals
Blood Component Removal -- Periodicals
Renal Dialysis -- Periodicals
Hémaphérèse -- Périodiques
Dialyse -- Périodiques
Sang -- Collecte et conservation -- Périodiques
616 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1744-9979;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1744-9987 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=tap ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/rd.asp?code=TAP&goto=journal ↗ - DOI:
- 10.1111/1744-9987.13490 ↗
- Languages:
- English
- ISSNs:
- 1744-9979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.642670
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15393.xml