Medium cut‐off dialyzers in a large population of hemodialysis patients in Colombia: COREXH registry. Issue 1 (29th May 2020)
- Record Type:
- Journal Article
- Title:
- Medium cut‐off dialyzers in a large population of hemodialysis patients in Colombia: COREXH registry. Issue 1 (29th May 2020)
- Main Title:
- Medium cut‐off dialyzers in a large population of hemodialysis patients in Colombia: COREXH registry
- Authors:
- Bunch, Alfonso
Sanchez, Ricardo
Nilsson, Lars‐Göran
Bernardo, Angelito A.
Vesga, Jasmin I.
Ardila, Fredy
Guerrero, Ivan M.
Sanabria, Rafael M.
Rivera, Angela S. - Abstract:
- Abstract: Expanded hemodialysis (HDx) provides increased clearance of conventional and large middle molecules through innovative medium cutoff (MCO) membranes. However, there is a paucity of real‐world data regarding the benefits and safety of HDx. This large observational study evaluated outcomes among patients in Colombia undergoing HDx at a extended dialysis clinical services provider. This was a prospective single cohort study of prevalent patients who were treated with HDx; baseline information was collected from the most recent data before patients were started on HDx. Patients were followed prospectively for 1 year for changes in serum albumin and other laboratory parameters compared with the baseline. Survival, hospitalization and safety were assessed from the start of HDx. A total of 1000 patients were invited to enroll; 992 patients met the inclusion criteria for data analysis and 638 patients completed the year of follow‐up. Seventy‐four (8%) patients died during 866 patient‐years (PY) of follow‐up; the mortality rate was 8.54 deaths/100 PY (95% confidence interval [CI], 6.8‐10.7). There were 673 hospitalization events with a rate of 0.79 events/PY (95% CI, 0.73‐0.85) with 6.91 hospital days/PY (95% CI, 6.74‐7.09). The observed variability from baseline and maximum average change in mean serum albumin levels were −1.8% and −3.5%, respectively. No adverse events were related to the MCO membrane. HDx using an MCO membrane maintains stable serum albumin levels and isAbstract: Expanded hemodialysis (HDx) provides increased clearance of conventional and large middle molecules through innovative medium cutoff (MCO) membranes. However, there is a paucity of real‐world data regarding the benefits and safety of HDx. This large observational study evaluated outcomes among patients in Colombia undergoing HDx at a extended dialysis clinical services provider. This was a prospective single cohort study of prevalent patients who were treated with HDx; baseline information was collected from the most recent data before patients were started on HDx. Patients were followed prospectively for 1 year for changes in serum albumin and other laboratory parameters compared with the baseline. Survival, hospitalization and safety were assessed from the start of HDx. A total of 1000 patients were invited to enroll; 992 patients met the inclusion criteria for data analysis and 638 patients completed the year of follow‐up. Seventy‐four (8%) patients died during 866 patient‐years (PY) of follow‐up; the mortality rate was 8.54 deaths/100 PY (95% confidence interval [CI], 6.8‐10.7). There were 673 hospitalization events with a rate of 0.79 events/PY (95% CI, 0.73‐0.85) with 6.91 hospital days/PY (95% CI, 6.74‐7.09). The observed variability from baseline and maximum average change in mean serum albumin levels were −1.8% and −3.5%, respectively. No adverse events were related to the MCO membrane. HDx using an MCO membrane maintains stable serum albumin levels and is safe in terms of nonoccurrence of dialyzer related adverse events. … (more)
- Is Part Of:
- Therapeutic apheresis and dialysis. Volume 25:Issue 1(2021)
- Journal:
- Therapeutic apheresis and dialysis
- Issue:
- Volume 25:Issue 1(2021)
- Issue Display:
- Volume 25, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2021-0025-0001-0000
- Page Start:
- 33
- Page End:
- 43
- Publication Date:
- 2020-05-29
- Subjects:
- expanded hemodialysis -- hemodialysis -- medium cutoff membranes -- real world evidence -- Colombia
Hemapheresis -- Periodicals
Dialysis -- Periodicals
Blood Component Removal -- Periodicals
Renal Dialysis -- Periodicals
Hémaphérèse -- Périodiques
Dialyse -- Périodiques
Sang -- Collecte et conservation -- Périodiques
616 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1744-9979;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1744-9987 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=tap ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/rd.asp?code=TAP&goto=journal ↗ - DOI:
- 10.1111/1744-9987.13506 ↗
- Languages:
- English
- ISSNs:
- 1744-9979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.642670
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15382.xml