Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients – comparison of two sampling methods. Issue 1 (26th October 2020)
- Record Type:
- Journal Article
- Title:
- Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients – comparison of two sampling methods. Issue 1 (26th October 2020)
- Main Title:
- Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients – comparison of two sampling methods
- Authors:
- van Oort, Pouline M. P.
White, Iain R.
Ahmed, Waqar
Johnson, Craig
Bannard-Smith, Jonathan
Felton, Timothy
Bos, Lieuwe D.
Goodacre, Royston
Dark, Paul
Fowler, Stephen J. - Abstract:
- Abstract : Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We identified potential sources of bias as illustrated in this figure. Abstract : Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in "real life" in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of dataAbstract : Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We identified potential sources of bias as illustrated in this figure. Abstract : Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in "real life" in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients. … (more)
- Is Part Of:
- Analyst. Volume 146:Issue 1(2021)
- Journal:
- Analyst
- Issue:
- Volume 146:Issue 1(2021)
- Issue Display:
- Volume 146, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 146
- Issue:
- 1
- Issue Sort Value:
- 2021-0146-0001-0000
- Page Start:
- 222
- Page End:
- 231
- Publication Date:
- 2020-10-26
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9an01134j ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15378.xml