Virtual 2D angiography from four-dimensional digital subtraction angiography (4D-DSA): A feasibility study. Issue 2 (April 2021)
- Record Type:
- Journal Article
- Title:
- Virtual 2D angiography from four-dimensional digital subtraction angiography (4D-DSA): A feasibility study. Issue 2 (April 2021)
- Main Title:
- Virtual 2D angiography from four-dimensional digital subtraction angiography (4D-DSA): A feasibility study
- Authors:
- Yu, Jay F
Pung, Leland
Minami, Hataka
Mueller, Kerstin
Khangura, Rajkamal
Darflinger, Robert
Hetts, Steven W
Cooke, Daniel L - Abstract:
- Background: Digital subtraction angiography (DSA) remains the gold standard for angiographic evaluation of cerebrovascular pathology, however, multiple acquisitions requiring additional time and radiation are often needed. In contrast, 3D-DSA provides volumetric information from a single injection but neglects temporal information. Four-dimensional-DSA (4D-DSA) combines temporal information of 2D-DSA with volumetric information of 3D-DSA to provide time-resolved tomographic 3D reconstructions, potentially reducing procedure time and radiation. This work evaluates the diagnostic quality of virtual single-frame 4D-DSA relative to 2D-DSA images by assessing clinicians' ability to evaluate cerebrovascular pathology. Methods: Single-frame images of four projections from 4D-DSA and their corresponding 2D-DSA images (n = 15) were rated by two neurointerventional radiologists. Images were graded based on diagnostic quality (0 = non-diagnostic, 1 = poor, 2 = acceptable, 3 = good). Dose area product (DAP) for each case was recorded for all 2D-DSA, 4D-DSA acquisitions, and the overall procedure. Results: The mean diagnostic quality of all four 4D-DSA projections from both raters was 1.75 while the mean of 2D-DSA projections was 2.8. Student's t-test revealed significant difference in diagnostic quality between 4D-DSA and 2D-DSA at all four projections (p < 0.001). On average 4D-DSA acquisitions accounted for 30% dose compared to the overall average aggregated dose per procedure.Background: Digital subtraction angiography (DSA) remains the gold standard for angiographic evaluation of cerebrovascular pathology, however, multiple acquisitions requiring additional time and radiation are often needed. In contrast, 3D-DSA provides volumetric information from a single injection but neglects temporal information. Four-dimensional-DSA (4D-DSA) combines temporal information of 2D-DSA with volumetric information of 3D-DSA to provide time-resolved tomographic 3D reconstructions, potentially reducing procedure time and radiation. This work evaluates the diagnostic quality of virtual single-frame 4D-DSA relative to 2D-DSA images by assessing clinicians' ability to evaluate cerebrovascular pathology. Methods: Single-frame images of four projections from 4D-DSA and their corresponding 2D-DSA images (n = 15) were rated by two neurointerventional radiologists. Images were graded based on diagnostic quality (0 = non-diagnostic, 1 = poor, 2 = acceptable, 3 = good). Dose area product (DAP) for each case was recorded for all 2D-DSA, 4D-DSA acquisitions, and the overall procedure. Results: The mean diagnostic quality of all four 4D-DSA projections from both raters was 1.75 while the mean of 2D-DSA projections was 2.8. Student's t-test revealed significant difference in diagnostic quality between 4D-DSA and 2D-DSA at all four projections (p < 0.001). On average 4D-DSA acquisitions accounted for 30% dose compared to the overall average aggregated dose per procedure. Conclusions: The difference in image quality between virtual single-frame 4D-DSA and their respective 2D-DSA images is statistically significant. Furthermore, 4D-DSA acquisitions require less radiation dose than conventional procedures with 2D-DSA acquisitions. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 27:Issue 2(2021)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 27:Issue 2(2021)
- Issue Display:
- Volume 27, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 2
- Issue Sort Value:
- 2021-0027-0002-0000
- Page Start:
- 307
- Page End:
- 313
- Publication Date:
- 2021-04
- Subjects:
- Digital subtraction angiography -- brain arteriovenous malformation(s) -- dural arteriovenous fistulas(s) -- intracerebral hemorrhage -- dose area product
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019920961604 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15370.xml