Predictors of Late Mortality in D‐Transposition of the Great Arteries After Atrial Switch Repair: Systematic Review and Meta‐Analysis. Issue 21 (5th November 2019)
- Record Type:
- Journal Article
- Title:
- Predictors of Late Mortality in D‐Transposition of the Great Arteries After Atrial Switch Repair: Systematic Review and Meta‐Analysis. Issue 21 (5th November 2019)
- Main Title:
- Predictors of Late Mortality in D‐Transposition of the Great Arteries After Atrial Switch Repair: Systematic Review and Meta‐Analysis
- Authors:
- Venkatesh, Prashanth
Evans, Arthur T.
Maw, Anna M.
Pashun, Raymond A.
Patel, Agam
Kim, Luke
Feldman, Dmitriy
Minutello, Robert
Wong, S. Chiu
Stribling, Judy C.
LaPar, Damian
Holzer, Ralf
Ginns, Jonathan
Bacha, Emile
Singh, Harsimran S. - Abstract:
- Abstract : Background: Existing data on predictors of late mortality and prevention of sudden cardiac death after atrial switch repair surgery for D‐transposition of the great arteries (D‐TGA) are heterogeneous and limited by statistical power. Methods and Results: We conducted a systematic review and meta‐analysis of 29 observational studies, comprising 5035 patients, that reported mortality after atrial switch repair with a minimum follow‐up of 10 years. We also examined 4 additional studies comprising 105 patients who reported rates of implantable cardioverter‐defibrillator therapy in this population. Average survival dropped to 65% at 40 years after atrial switch repair, with sudden cardiac death accounting for 45% of all reported deaths. Mortality was significantly lower in cohorts that were more recent and operated on younger patients. Patient‐level risk factors for late mortality were history of supraventricular tachycardia (odds ratio [OR] 3.8, 95% CI 1.4–10.7), Mustard procedure compared with Senning (OR 2.9, 95% CI 1.9–4.5) and complex D‐TGA compared with simple D‐TGA (OR 4.4, 95% CI 2.2–8.8). Significant risk factors for sudden cardiac death were history of supraventricular tachycardia (OR 4.7, 95% CI 2.2–9.8), Mustard procedure (OR 2.2, 95% CI 1.1–4.1), and complex D‐TGA (OR 5.7, 95% CI 1.8–18.0). Out of a total 124 implantable cardioverter‐defibrillator discharges over 330 patient‐years in patients with implantable cardioverter‐defibrillators for primaryAbstract : Background: Existing data on predictors of late mortality and prevention of sudden cardiac death after atrial switch repair surgery for D‐transposition of the great arteries (D‐TGA) are heterogeneous and limited by statistical power. Methods and Results: We conducted a systematic review and meta‐analysis of 29 observational studies, comprising 5035 patients, that reported mortality after atrial switch repair with a minimum follow‐up of 10 years. We also examined 4 additional studies comprising 105 patients who reported rates of implantable cardioverter‐defibrillator therapy in this population. Average survival dropped to 65% at 40 years after atrial switch repair, with sudden cardiac death accounting for 45% of all reported deaths. Mortality was significantly lower in cohorts that were more recent and operated on younger patients. Patient‐level risk factors for late mortality were history of supraventricular tachycardia (odds ratio [OR] 3.8, 95% CI 1.4–10.7), Mustard procedure compared with Senning (OR 2.9, 95% CI 1.9–4.5) and complex D‐TGA compared with simple D‐TGA (OR 4.4, 95% CI 2.2–8.8). Significant risk factors for sudden cardiac death were history of supraventricular tachycardia (OR 4.7, 95% CI 2.2–9.8), Mustard procedure (OR 2.2, 95% CI 1.1–4.1), and complex D‐TGA (OR 5.7, 95% CI 1.8–18.0). Out of a total 124 implantable cardioverter‐defibrillator discharges over 330 patient‐years in patients with implantable cardioverter‐defibrillators for primary prevention, only 8% were appropriate. Conclusions: Patient‐level risk of both mortality and sudden cardiac death after atrial switch repair are significantly increased by history of supraventricular tachycardia, Mustard procedure, and complex D‐TGA. This knowledge may help refine current selection practices for primary prevention implantable cardioverter‐defibrillator implantation, given disproportionately high rates of inappropriate discharges. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 8:Issue 21(2019)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 8:Issue 21(2019)
- Issue Display:
- Volume 8, Issue 21 (2019)
- Year:
- 2019
- Volume:
- 8
- Issue:
- 21
- Issue Sort Value:
- 2019-0008-0021-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-11-05
- Subjects:
- atrial switch -- D‐transposition of the great arteries -- long‐term outcomes -- mustard -- senning -- sudden cardiac death
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.119.012932 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15367.xml