In-vivo tongue stiffness measured by aspiration: Resting vs general anesthesia. (4th January 2021)
- Record Type:
- Journal Article
- Title:
- In-vivo tongue stiffness measured by aspiration: Resting vs general anesthesia. (4th January 2021)
- Main Title:
- In-vivo tongue stiffness measured by aspiration: Resting vs general anesthesia
- Authors:
- Kappert, K.D.R.
Connesson, N.
Elahi, S.A.
Boonstra, S.
Balm, A.J.M.
van der Heijden, F.
Payan, Y. - Abstract:
- Abstract: Tongue cancer treatment often results in impaired speech, swallowing, or mastication. Simulating the effect of treatments can help the patient and the treating physician to understand the effects and impact of the intervention. To simulate deformations of the tongue, identifying accurate mechanical properties of tissue is essential. However, not many succeeded in characterizing in-vivo tongue stiffness. Those who did, measured the tongue At Rest (AR), in which muscle tone subsides even if muscles are not willingly activated. We expected to find an absolute rest state in participants 'under General Anesthesia' (GA). We elaborated on previous work by measuring the mechanical behavior of the in-vivo tongue under aspiration using an improved volume-based method. Using this technique, 5 to 7 measurements were performed on 10 participants both AR and under GA. The obtained Pressure-Shape curves were first analyzed using the initial slope and its variations. Hereafter, an inverse Finite Element Analysis (FEA) was applied to identify the mechanical parameters using the Yeoh, Gent, and Ogden hyperelastic models. The measurements AR provided a mean Young's Modulus of 1638 Pa (min 1035 – max 2019) using the Yeoh constitutive model, which is in line with previous ex-vivo measurements. However, while hoping to find a rest state under GA, the tongue unexpectedly appeared to be approximately 2 to 2.5 times stiffer under GA than AR. Explanations for this were sought by examiningAbstract: Tongue cancer treatment often results in impaired speech, swallowing, or mastication. Simulating the effect of treatments can help the patient and the treating physician to understand the effects and impact of the intervention. To simulate deformations of the tongue, identifying accurate mechanical properties of tissue is essential. However, not many succeeded in characterizing in-vivo tongue stiffness. Those who did, measured the tongue At Rest (AR), in which muscle tone subsides even if muscles are not willingly activated. We expected to find an absolute rest state in participants 'under General Anesthesia' (GA). We elaborated on previous work by measuring the mechanical behavior of the in-vivo tongue under aspiration using an improved volume-based method. Using this technique, 5 to 7 measurements were performed on 10 participants both AR and under GA. The obtained Pressure-Shape curves were first analyzed using the initial slope and its variations. Hereafter, an inverse Finite Element Analysis (FEA) was applied to identify the mechanical parameters using the Yeoh, Gent, and Ogden hyperelastic models. The measurements AR provided a mean Young's Modulus of 1638 Pa (min 1035 – max 2019) using the Yeoh constitutive model, which is in line with previous ex-vivo measurements. However, while hoping to find a rest state under GA, the tongue unexpectedly appeared to be approximately 2 to 2.5 times stiffer under GA than AR. Explanations for this were sought by examining drugs administered during GA, blood flow, perfusion, and upper airway reflexes, but neither of these explanations could be confirmed. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 114(2021)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 114(2021)
- Issue Display:
- Volume 114, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 114
- Issue:
- 2021
- Issue Sort Value:
- 2021-0114-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-04
- Subjects:
- Tongue stiffness -- General anesthesia -- Tissue parameters -- Aspiration device -- Tongue cancer
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2020.110147 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15359.xml