Comparison of the Major Clinical Outcomes for the Use of Endeavor® and Resolute Integrity® Zotarolimus-Eluting Stents During a Three-Year Follow-up. Issue 1 (6th February 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of the Major Clinical Outcomes for the Use of Endeavor® and Resolute Integrity® Zotarolimus-Eluting Stents During a Three-Year Follow-up. Issue 1 (6th February 2020)
- Main Title:
- Comparison of the Major Clinical Outcomes for the Use of Endeavor® and Resolute Integrity® Zotarolimus-Eluting Stents During a Three-Year Follow-up
- Authors:
- Kim, Yong Hoon
Her, Ae-Young
Rha, Seung-Woon
Choi, Byoung Geol
Choi, Se Yeon
Byun, Jae Kyeong
Park, Yoonjee
Kang, Dong Oh
Jang, Won Young
Kim, Woohyeun
Choi, Cheol Ung
Park, Chang Gyu
Seo, Hong Seog - Abstract:
- Background: Endeavor®-zotarolimus-eluting stent (E-ZES) was the first ZES to be developed, and Resolute integrity®-ZES (I-ZES) has been developed more recently. Comparative studies on long-term usage of these two ZESs have been rare. Objectives: The aim of this study was to compare the efficacy and safety of E-ZES and I-ZES during a long-term follow-up of patients who underwent percutaneous coronary intervention (PCI). Methods: A total of 767 patients who underwent PCI with E-ZES or I-ZES were eligible for this study. The primary endpoint was the occurrence of major adverse cardiac events (MACEs), defined as the composite of all-cause death, non-fatal myocardial infarction (MI), and any repeat revascularization. The secondary endpoint was stent thrombosis (ST). Results: After propensity score-matched (PSM) analysis, two PSM groups (193 pairs, n = 386, C-statistic = 0.824) were generated. During the 3-year follow-up period, the cumulative incidence of MACEs (hazard ratio [HR], 0.837; 95% confidence interval [CI], 0.464–1.508; p = 0.553) and ST (HR, 0.398; 95% CI, 0.077–2.052; p = 0.271) was similar for the E-ZES and I-ZES groups. Additionally, the cumulative incidences of all-cause death, cardiac death, non-fatal MI, and any repeat revascularization were not significantly different between the two groups. Conclusions: Although I-ZES utilizes a more advanced stent platform, stent design, and polymer system than E-ZES, both the ZESs showed comparable efficacy and safety duringBackground: Endeavor®-zotarolimus-eluting stent (E-ZES) was the first ZES to be developed, and Resolute integrity®-ZES (I-ZES) has been developed more recently. Comparative studies on long-term usage of these two ZESs have been rare. Objectives: The aim of this study was to compare the efficacy and safety of E-ZES and I-ZES during a long-term follow-up of patients who underwent percutaneous coronary intervention (PCI). Methods: A total of 767 patients who underwent PCI with E-ZES or I-ZES were eligible for this study. The primary endpoint was the occurrence of major adverse cardiac events (MACEs), defined as the composite of all-cause death, non-fatal myocardial infarction (MI), and any repeat revascularization. The secondary endpoint was stent thrombosis (ST). Results: After propensity score-matched (PSM) analysis, two PSM groups (193 pairs, n = 386, C-statistic = 0.824) were generated. During the 3-year follow-up period, the cumulative incidence of MACEs (hazard ratio [HR], 0.837; 95% confidence interval [CI], 0.464–1.508; p = 0.553) and ST (HR, 0.398; 95% CI, 0.077–2.052; p = 0.271) was similar for the E-ZES and I-ZES groups. Additionally, the cumulative incidences of all-cause death, cardiac death, non-fatal MI, and any repeat revascularization were not significantly different between the two groups. Conclusions: Although I-ZES utilizes a more advanced stent platform, stent design, and polymer system than E-ZES, both the ZESs showed comparable efficacy and safety during the 3-year follow-up period in this single-center, all-comers registry. However, further large-scaled, randomized, well-controlled trials with long-term follow-up are needed to verify these results. … (more)
- Is Part Of:
- Global heart. Volume 15:Issue 1(2020)
- Journal:
- Global heart
- Issue:
- Volume 15:Issue 1(2020)
- Issue Display:
- Volume 15, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2020-0015-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-02-06
- Subjects:
- Clinical outcomes -- Drug-eluting stent -- Zotarolimus
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Prevention -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
Cardiovascular system -- Diseases -- Prevention
Cardiovascular Diseases -- prevention & control -- Periodicals
Cardiovascular Diseases -- Periodicals
Developing Countries -- Periodicals
Electronic journals
Electronic journals
Periodicals
616.1005 - Journal URLs:
- https://globalheartjournal.com/ ↗
https://www.world-heart-federation.org/global-heart/ ↗
http://www.sciencedirect.com/science/journal/22118160 ↗ - DOI:
- 10.5334/gh.374 ↗
- Languages:
- English
- ISSNs:
- 2211-8160
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15353.xml