848Ultrasound-guided axillary vein puncture feasibility for complex cardiac devices implantation. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- 848Ultrasound-guided axillary vein puncture feasibility for complex cardiac devices implantation. (18th June 2020)
- Main Title:
- 848Ultrasound-guided axillary vein puncture feasibility for complex cardiac devices implantation
- Authors:
- Bun, S-S
Squara, F
Scarlatti, D
Theodore, G
Latcu, D G
Hasni, K
Benaich, F A
Enache, B
Saooudi, N
Allouche, E
Diakite, M
Ferrari, E - Abstract:
- Abstract: Background: The axillary route use for cardiac devices implantation has recently expanded either with fluoroscopy or ultrasounds guidance. Few studies included defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures for ultrasound-guided axillary vein puncture (UGVP). Puropose: To assess the feasibility/safety of UGVP for complex cardiac devices implantation including CRT/ICD. Methods: Consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by three operators (one experienced and two fellows). Guidewires insertion time (from lidocaïne administration), and complications were systematically studied. A group of patients implanted with alternative techniques was used for comparison (cephalic, subclavian). Results: In 176 consecutive patients in whom UGVP was used, a total of 68 complex procedures were analyzed (74 ± 8 y, male 61 %) with 138 leads implanted including 42 ICD, 48 CRT and 16 upgrade procedures. A majority (83 %) was under anti-thrombotic therapy. UGVP was successful in 96.8 %. Mean insertion time for 1.78 guidewires per patient was 4.4 ± 4.4 min. Guidewires insertion time reached its plateau after 10 patients. One pocket hematoma (1.4 %) was drained during a mean follow-up of 12 ± 5 months. The control group included 28 patients (12 subclavian, 16 cephalic; 15 ICD, 18 CRT, 4 upgrade procedures), with a mean insertion time of 10 ± 8 min, for 1.95 guidewires per patient (p <Abstract: Background: The axillary route use for cardiac devices implantation has recently expanded either with fluoroscopy or ultrasounds guidance. Few studies included defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures for ultrasound-guided axillary vein puncture (UGVP). Puropose: To assess the feasibility/safety of UGVP for complex cardiac devices implantation including CRT/ICD. Methods: Consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by three operators (one experienced and two fellows). Guidewires insertion time (from lidocaïne administration), and complications were systematically studied. A group of patients implanted with alternative techniques was used for comparison (cephalic, subclavian). Results: In 176 consecutive patients in whom UGVP was used, a total of 68 complex procedures were analyzed (74 ± 8 y, male 61 %) with 138 leads implanted including 42 ICD, 48 CRT and 16 upgrade procedures. A majority (83 %) was under anti-thrombotic therapy. UGVP was successful in 96.8 %. Mean insertion time for 1.78 guidewires per patient was 4.4 ± 4.4 min. Guidewires insertion time reached its plateau after 10 patients. One pocket hematoma (1.4 %) was drained during a mean follow-up of 12 ± 5 months. The control group included 28 patients (12 subclavian, 16 cephalic; 15 ICD, 18 CRT, 4 upgrade procedures), with a mean insertion time of 10 ± 8 min, for 1.95 guidewires per patient (p < 0.0005). Conclusion: UGVP is feasible and safe even for complex device implantations including CRT/ICD and upgrade procedures. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.128 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml