P518Inappropriate shocks in atrial fibrillation patients: are they really deleterious?. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- P518Inappropriate shocks in atrial fibrillation patients: are they really deleterious?. (18th June 2020)
- Main Title:
- P518Inappropriate shocks in atrial fibrillation patients: are they really deleterious?
- Authors:
- Marinheiro, R
Parreira, L
Amador, P
Mesquita, D
Farinha, J
Fonseca, M
Esteves, A
Ferreira, J
Lopes, C
Caria, R - Abstract:
- Abstract: Introduction: Data suggest inappropriate defibrillator shocks are associated with a higher risk of all-cause mortality, particularly those delivered for atrial fibrillation (AF). However, the impact of inappropriate shocks has not been studied specifically in a population with AF. Aims: to determine if AF-triggered inappropriate shocks are associated with long- term mortality in patients with AF and defibrillators implanted for primary prevention. Methods: Retrospective single-center study. We analyzed all patients with defibrillators implanted for primary prevention in whom AF was diagnosed until the end of 2017. The cause of inappropriate shocks was evaluated by analysis of the stored intracardiac electrogram. Basal characteristics, cardiovascular risk factors, left ventricle ejection fraction, heart failure etiology (ischemic and non-ischemic), kidney function (creatinine) and medication were evaluated. Death was assessed during the follow-up. Results: We studied 177 patients [median age 66 years (IQR 59-71); 82% male], with defibrillators and AF. AF was diagnosed before defibrillator implantation in 131 patients (74%) and after the implantation in the remaining 46 (26%). Inappropriate shocks occurred in 31 patients and 24 (14%) were caused by AF with rapid ventricular response: 13 patients with previously diagnosed AF and 11 with new-onset AF. During a median follow-up of 65 (IQR: 36-104) months, 74 patients died. Multivariate Cox-regression analysisAbstract: Introduction: Data suggest inappropriate defibrillator shocks are associated with a higher risk of all-cause mortality, particularly those delivered for atrial fibrillation (AF). However, the impact of inappropriate shocks has not been studied specifically in a population with AF. Aims: to determine if AF-triggered inappropriate shocks are associated with long- term mortality in patients with AF and defibrillators implanted for primary prevention. Methods: Retrospective single-center study. We analyzed all patients with defibrillators implanted for primary prevention in whom AF was diagnosed until the end of 2017. The cause of inappropriate shocks was evaluated by analysis of the stored intracardiac electrogram. Basal characteristics, cardiovascular risk factors, left ventricle ejection fraction, heart failure etiology (ischemic and non-ischemic), kidney function (creatinine) and medication were evaluated. Death was assessed during the follow-up. Results: We studied 177 patients [median age 66 years (IQR 59-71); 82% male], with defibrillators and AF. AF was diagnosed before defibrillator implantation in 131 patients (74%) and after the implantation in the remaining 46 (26%). Inappropriate shocks occurred in 31 patients and 24 (14%) were caused by AF with rapid ventricular response: 13 patients with previously diagnosed AF and 11 with new-onset AF. During a median follow-up of 65 (IQR: 36-104) months, 74 patients died. Multivariate Cox-regression analysis demonstrated inappropriate shocks caused by AF were not independently related with death (adjusted HR 0.53; CI 0.23-1.23, p = 0.14). Kaplan-Meier survival curve demonstrated patients with AF-triggered inappropriate shocks had a better survival comparing to those with AF but without inappropriate shocks (logrank, p = 0.03) (figure). Conclusions: In this group of AF patients, inappropriate shocks caused by AF did not increase the risk of death. Instead, these patients had a better survival comparing to those with AF but no shocks, probably due to a re-evaluation of the patient´s status and subsequent closer medical monitoring, strictly control of symptoms and optimization of drug treatment. These results demonstrate that inappropriate shocks are probably not deleterious per si through a direct mechanism. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.039 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml