250Efficacy of multi-electrode linear irreversible electroporation. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- 250Efficacy of multi-electrode linear irreversible electroporation. (18th June 2020)
- Main Title:
- 250Efficacy of multi-electrode linear irreversible electroporation
- Authors:
- Buist, T J
Groen, M H A
Wittkampf, F H M
Loh, K P
Doevendans, P A
Van Es, R
Elvan, A - Abstract:
- Abstract: Background: We investigated the efficacy of linear irreversible electroporation (IRE) ablation in a porcine model. Methods: The study was performed in 6 pigs (weight 60-75kg). After median sternotomy and opening of the pericardium, a pericardial cradle was formed and filled with blood. A linear 7 polar 7F electrode catheter with 2.5mm electrodes and 2.5mm inter-electrode spacing was placed in good epicardial contact. A single IRE application was delivered using 50 Joules (J) at 1 site and 100 J at 2 other sites, in random sequence, using a standard monophasic defibrillator connected to all 7 electrodes connected in parallel. The pericardium and thorax were closed and after 3 weeks survival animals were euthanized. 82 histological sections from all 18 electroporation lesions were analyzed. Results: A total of seven 50 J and fourteen 100 J epicardial IRE applications were performed. Mean peak voltages at 50 J and 100 J were 1079.2 V ± 81.1 and 1609.5 V ± 56.8, with a mean peak current of 15.4 A ± 2.3 and 20.2 A ± 1.7, respectively. Median depth of the 50J and 100J lesions were 3.2 mm (interquartile range [IQR], 3.1 – 3.6) and 5.5 mm (IQR, 4.6 – 6.6) (P < 0.001), respectively. Median lesion width of the 50J and 100J lesions were 3.9 mm (IQR, 3.7 – 4.8) and 5.4 mm (IQR, 5.0 - 6.3), respectively(P < 0.001). Longitudinal sections showed continuous lesions for 100J lesions. Conclusion: Epicardial linear application of IRE pulses is effective in creating continuousAbstract: Background: We investigated the efficacy of linear irreversible electroporation (IRE) ablation in a porcine model. Methods: The study was performed in 6 pigs (weight 60-75kg). After median sternotomy and opening of the pericardium, a pericardial cradle was formed and filled with blood. A linear 7 polar 7F electrode catheter with 2.5mm electrodes and 2.5mm inter-electrode spacing was placed in good epicardial contact. A single IRE application was delivered using 50 Joules (J) at 1 site and 100 J at 2 other sites, in random sequence, using a standard monophasic defibrillator connected to all 7 electrodes connected in parallel. The pericardium and thorax were closed and after 3 weeks survival animals were euthanized. 82 histological sections from all 18 electroporation lesions were analyzed. Results: A total of seven 50 J and fourteen 100 J epicardial IRE applications were performed. Mean peak voltages at 50 J and 100 J were 1079.2 V ± 81.1 and 1609.5 V ± 56.8, with a mean peak current of 15.4 A ± 2.3 and 20.2 A ± 1.7, respectively. Median depth of the 50J and 100J lesions were 3.2 mm (interquartile range [IQR], 3.1 – 3.6) and 5.5 mm (IQR, 4.6 – 6.6) (P < 0.001), respectively. Median lesion width of the 50J and 100J lesions were 3.9 mm (IQR, 3.7 – 4.8) and 5.4 mm (IQR, 5.0 - 6.3), respectively(P < 0.001). Longitudinal sections showed continuous lesions for 100J lesions. Conclusion: Epicardial linear application of IRE pulses is effective in creating continuous deep lesions. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.160 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml