1244Feasibility, safety and efficacy of tailoring ablation index to left atrial wall thickness (lawt) during atrial fibrillation ablation. The Ablate By-LAW Study. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- 1244Feasibility, safety and efficacy of tailoring ablation index to left atrial wall thickness (lawt) during atrial fibrillation ablation. The Ablate By-LAW Study. (18th June 2020)
- Main Title:
- 1244Feasibility, safety and efficacy of tailoring ablation index to left atrial wall thickness (lawt) during atrial fibrillation ablation. The Ablate By-LAW Study
- Authors:
- Teres, C
Jauregui, B
Soto-Iglesias, D
Ordonez, A
Chauca, A
Ramirez, C
Oller, G
Jornet, A
Palet, J
Padro, J
Maldonado, G
Panaro, A
Carballo, J
Penela, D
Berruezo, A - Abstract:
- Abstract: Funding Acknowledgements: Dr Teres was funded by Swiss Heartrhythm Foundation Introduction: Circumferential pulmonary vein isolation (PVI) has become a mainstay in the treatment of atrial fibrillation (AF). The utility of ablation index (AI) to dose radiofrequency delivery for the reduction of AF recurrences has already been proven with a target AI ≥ 400 at the posterior wall and ≥550 at the anterior Wall. Nevertheless, the left atrial wall is a thin, heterogeneous structure with an important inter and intra-patient variability of LAWT. Objective: To determine if adapting AI to atrial wall thickness (AWT) is feasible, effective and safe during AF ablation. Methods: Single-Center study that included 80 consecutive patients referred for a first paroxysmal AF ablation that was performed with a single catheter approach with the intention to reduce vascular access complication rate. All patients had a MDCT prior to the ablation procedure. LAWT maps were semi-automatically computed from the MDCT as the local distance between the LA endo and epicardium. All procedures were performed under general anesthesia with a high-rate low-volume ventilation protocol for obtaining higher catheter stability. The transeptal puncture was TEE-guided. During the procedure, the WT map was fused with the LA anatomy using CARTO-merge. LAWT was categorized into 1mm-layers and the AI was titrated to the local atrial WT as follows: Thickness < 1 mm (red): 300; 1-2 mm (yellow): 350; 2-3 mmAbstract: Funding Acknowledgements: Dr Teres was funded by Swiss Heartrhythm Foundation Introduction: Circumferential pulmonary vein isolation (PVI) has become a mainstay in the treatment of atrial fibrillation (AF). The utility of ablation index (AI) to dose radiofrequency delivery for the reduction of AF recurrences has already been proven with a target AI ≥ 400 at the posterior wall and ≥550 at the anterior Wall. Nevertheless, the left atrial wall is a thin, heterogeneous structure with an important inter and intra-patient variability of LAWT. Objective: To determine if adapting AI to atrial wall thickness (AWT) is feasible, effective and safe during AF ablation. Methods: Single-Center study that included 80 consecutive patients referred for a first paroxysmal AF ablation that was performed with a single catheter approach with the intention to reduce vascular access complication rate. All patients had a MDCT prior to the ablation procedure. LAWT maps were semi-automatically computed from the MDCT as the local distance between the LA endo and epicardium. All procedures were performed under general anesthesia with a high-rate low-volume ventilation protocol for obtaining higher catheter stability. The transeptal puncture was TEE-guided. During the procedure, the WT map was fused with the LA anatomy using CARTO-merge. LAWT was categorized into 1mm-layers and the AI was titrated to the local atrial WT as follows: Thickness < 1 mm (red): 300; 1-2 mm (yellow): 350; 2-3 mm (green): 400; 3-4 mm (blue): 450; > 4 mm (purple): 450 (Figure). Maximal inter-lesion distance was set at 6 mm. VisiTag settings were: catheter position stability: minimum time 3 s, maximum range 4 mm; force over time: 25%, minimum force 3 g; lesion tag size: 3 mm. Respiration training was not possible due to the high catheter stability. The circumferential ablation line was designed in a personalized fashion to avoid thicker regions. Results: 80 patients [41 (51, 2 %) male, age 60± 11 years] were included. Mean LVEF was 59 ± 5 %, Mean LA diameter 39, 1 ± 5, 8 mm, Mean LAWT was 1.36 ± 0.63 mm. Mean AI was 352 ± 36 on the RPVs and 356 ± 36 on the LPVs. Procedure time was 60, 0 min (IQR 51-70). Fluoroscopy time was 58, 5 s (35-97, 5). First pass isolation was obtained in 72 (90%) of the RPVs and 75 (93, 8%) of the LPVs. Conclusions: the present study, assessing a novel, personalized protocol for radiofrequency titration during atrial fibrillation ablation, shows a high rate of first pass isolation with a lower need for RF energy delivery and lower procedure requirements, as compared to previous PV ablation protocols. Further studies are needed to evaluate the long-term results of this approach. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.238 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml