P1026Second-generation visually guided laser balloon ablation system for pulmonary vein isolation: Learning curve, safety and efficacy: The MERLIN registry. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- P1026Second-generation visually guided laser balloon ablation system for pulmonary vein isolation: Learning curve, safety and efficacy: The MERLIN registry. (18th June 2020)
- Main Title:
- P1026Second-generation visually guided laser balloon ablation system for pulmonary vein isolation: Learning curve, safety and efficacy: The MERLIN registry
- Authors:
- Heeger, C H
Phan, H L P
Meyer-Saraei, R M S
Fink, T F
Sciacca, V S
Liosis, S L
Brueggemann, B B
Grosse, N G
Fahimi, B F
Sano, M S
Kuck, K H K
Ouyang, F O
Vogler, J V
Eitel, C E
Tilz, R R T - Abstract:
- Abstract: Funding Acknowledgements: Cardiofocus Background: Radiofrequency (RF) based pulmonary vein isolation (PVI) results in favourable clinical outcome, although its complexity demands a long learning curve. Balloon-based systems, have been developed to possibly solve these limitations. The second-generation laser balloon (LB2) offers optimized features for improved tissue contact and visibility. Purpose: We determined safety, efficacy and learning curve of the LB2 for PVI. Method: A total of 45 consecutive patients (89% persistent AF) were prospectively enrolled and divided in three groups (T1, T2, T3) of n = 15 patients per group. All patients underwent PVI using the LB2 by two operators. The operators were experienced in RF and cryothermal procedures, but not in laser ablations. Results: A total 174/177 PVs (98%) were successfully isolated. The median procedure time significantly declined from 132 (114, 158) to 119 (102, 127) and 91 (86, 105) min in T 1–3, respectively (P = 0.0009). Similarly, the median fluoroscopy time significantly decreased from T1 until T3 (22 (17, 27) vs. 21 (16, 24) vs. 13 (10, 17) min, respectively, P = 0.045. Adverse events occurred in 6.7% with a trend towards a lower complication rate with increasing experience. Conclusion: The LB2 was safe and effective for PVI even for operators without any previous experience in laser balloon based PVI. Procedure time LA dwelling time and fluoroscopy time decreased after a learning curve of 15 cases.
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.307 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml