- Abstract: Funding Acknowledgements: Medtronic OnBehalf: PainFree SST Background: Anti-tachycardia Pacing (ATP) is an established therapy that terminates VT without the need for painful ICD shocks. Here we use the data from PainFree SST clinical trial to evaluate the ATP success rate by device type, indication and MCL. Methods: Spontaneous episodes that were detected by ICD or CRT-D devices in the VT, fast VT and VF zones were included in the analysis. Episodes successfully terminated by ATP were deemed as having ATP success. Using the GEE method, ATP success rate and its 95% CI were calculated for device types, indications and ventricular MCL. Results: Of the 2770 enrolled patients (79% male, average age 65 years), 1699 (61%) were implanted with an ICD and 1071 (39%) with a CRT-D system; 1917 (69%) were reported as primary prevention and 847 (31%) were secondary prevention patients. For all MVT episodes, the ATP success rate was similar between ICD and CRT-D devices (82.3% vs 80.3%, p = 0.74). Patients with secondary prevention had a higher ATP success rate compared to those with primary prevention but the difference was not statistically significant (84.4% vs 76.8%, p = 0.16). Regardless of device type and indication, ATP success rate was significantly higher in the slower VTs (MCL ≥ 320 ms) compared to the faster VTs (MCL ≥ 240 to < 320 ms) (89.2% vs 73.7%, p < 0.0001). Conclusion: We found that ATP had a greater than 80% rate of success for terminating ventricularAbstract: Funding Acknowledgements: Medtronic OnBehalf: PainFree SST Background: Anti-tachycardia Pacing (ATP) is an established therapy that terminates VT without the need for painful ICD shocks. Here we use the data from PainFree SST clinical trial to evaluate the ATP success rate by device type, indication and MCL. Methods: Spontaneous episodes that were detected by ICD or CRT-D devices in the VT, fast VT and VF zones were included in the analysis. Episodes successfully terminated by ATP were deemed as having ATP success. Using the GEE method, ATP success rate and its 95% CI were calculated for device types, indications and ventricular MCL. Results: Of the 2770 enrolled patients (79% male, average age 65 years), 1699 (61%) were implanted with an ICD and 1071 (39%) with a CRT-D system; 1917 (69%) were reported as primary prevention and 847 (31%) were secondary prevention patients. For all MVT episodes, the ATP success rate was similar between ICD and CRT-D devices (82.3% vs 80.3%, p = 0.74). Patients with secondary prevention had a higher ATP success rate compared to those with primary prevention but the difference was not statistically significant (84.4% vs 76.8%, p = 0.16). Regardless of device type and indication, ATP success rate was significantly higher in the slower VTs (MCL ≥ 320 ms) compared to the faster VTs (MCL ≥ 240 to < 320 ms) (89.2% vs 73.7%, p < 0.0001). Conclusion: We found that ATP had a greater than 80% rate of success for terminating ventricular tachycardias overall. Slower VTs was significantly associated with a higher ATP success rate regardless of device type and indication compared to faster VTs. For faster VTs with a MCL ≥ 240 to < 320 ms, the ATP success rate was still successful at terminating VT more than 70% of the time. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.343 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml