P1409Effectiveness of atrial fibrillation ablation using a contact force stability module with contact force or non-contact force catheter. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- P1409Effectiveness of atrial fibrillation ablation using a contact force stability module with contact force or non-contact force catheter. (18th June 2020)
- Main Title:
- P1409Effectiveness of atrial fibrillation ablation using a contact force stability module with contact force or non-contact force catheter
- Authors:
- Khaykin, Y
Alipour, P
Azizi, Z
Avoulov, A
Jansen, C
Donegan, S
Morris, S
Nath, S
Tamjidi, S
Varah, N
Pantano, A
Verma, A
Weaver, B
Hunter, T D - Abstract:
- Abstract: Funding Acknowledgements: This study was funded by Biosense Webster, Inc. Background: Catheter ablation is a mainstream treatment option for atrial fibrillation (AF). Recently, contact force (CF) enabled ablation catheters and a stability module were developed to allow for real-time CF sensing and improvement of catheter-tissue stability, which is important for achieving an optimal clinical outcome. We assessed the relative effectiveness of these new technologies, as well as the optimal CF stability parameters, in a real-world setting. Purpose: To compare the clinical effectiveness of AF ablations performed with a CF catheter using location stability settings of 2.5 mm maximum distance for 12 s minimum (2.5/12) vs. a non-CF catheter with settings of 3 mm for 7 s (3/7). Methods: Within 1/14–4/18, 176 de novo AF ablations using either a CF catheter with stability settings of 2.5/12 (n = 92, 5/16–4/18) or a non-CF catheter with stability settings of 3/7 (n = 84, 1/14–3/14) were performed by a single operator at a Canadian medical center. Patients routinely wore 48 hour Holter monitors every three months through the first year. The primary measures of effectiveness were Kaplan-Meier (KM) survival estimates of freedom from AF/atrial tachycardia (AT)/atrial flutter (AFL) recurrence after a 3-month blanking period and reablation. Results: The CF group was 62.9 ± 10.0 years old, 57.6% male, and 66.3% paroxysmal (PAF). The non-CF group was 61.6 ± 9.9 years old, 63.1% male,Abstract: Funding Acknowledgements: This study was funded by Biosense Webster, Inc. Background: Catheter ablation is a mainstream treatment option for atrial fibrillation (AF). Recently, contact force (CF) enabled ablation catheters and a stability module were developed to allow for real-time CF sensing and improvement of catheter-tissue stability, which is important for achieving an optimal clinical outcome. We assessed the relative effectiveness of these new technologies, as well as the optimal CF stability parameters, in a real-world setting. Purpose: To compare the clinical effectiveness of AF ablations performed with a CF catheter using location stability settings of 2.5 mm maximum distance for 12 s minimum (2.5/12) vs. a non-CF catheter with settings of 3 mm for 7 s (3/7). Methods: Within 1/14–4/18, 176 de novo AF ablations using either a CF catheter with stability settings of 2.5/12 (n = 92, 5/16–4/18) or a non-CF catheter with stability settings of 3/7 (n = 84, 1/14–3/14) were performed by a single operator at a Canadian medical center. Patients routinely wore 48 hour Holter monitors every three months through the first year. The primary measures of effectiveness were Kaplan-Meier (KM) survival estimates of freedom from AF/atrial tachycardia (AT)/atrial flutter (AFL) recurrence after a 3-month blanking period and reablation. Results: The CF group was 62.9 ± 10.0 years old, 57.6% male, and 66.3% paroxysmal (PAF). The non-CF group was 61.6 ± 9.9 years old, 63.1% male, and 76.2% PAF. Procedural complications consisted of a single vascular access complication in the non-CF group. The 12-month estimate of freedom from AF/AT/AFL recurrence was 79.4% in the CF group vs. 64.8% in the non-CF group (p = 0.058 for difference in survival over time). 12-month freedom from reablation was 90.4% in the CF group vs. 70.5% in the non-CF group (p = 0.002). Conclusion: CF ablation with more stringent stability settings of 2.5/12 was more effective than non-CF ablation with stability settings of 3/7, likely attributable to the CF catheter enabling visualization of catheter-tissue contact and the stability module facilitating maintenance of CF stability during ablation. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.092 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15328.xml