A comparative study of high capacity tensiometer designs. (December 2020)
- Record Type:
- Journal Article
- Title:
- A comparative study of high capacity tensiometer designs. (December 2020)
- Main Title:
- A comparative study of high capacity tensiometer designs
- Authors:
- Mendes, J.
Gallipoli, D.
Boeck, F.
Tarantino, A. - Abstract:
- Abstract: The High Capacity Tensiometer (HCT) is a soil sensor that can measure large negative pore-water pressures, i.e. in excess of −1 MPa, and is a key instrument for monitoring ground-atmosphere interactions. The design of HCTs has not changed since the first prototype was proposed in the 1990s and still includes three main components, namely a high air-entry value porous filter, a small water reservoir and a pressure transducer, which are all encased inside a protective sheath. Despite many successful examples of measurement of pore-water tension in the laboratory and the field, there are essentially no commercially available HCTs for industrial applications. The rare utilization of HCTs in engineering practice has always relied on bespoke devices that have been purposely designed by research laboratories or suppliers of soil sensors. The dissemination of HCTs into engineering practice has been further hindered by the relatively poor understanding of sensor design and its impact on the reliability of measurements. To overcome such gap of knowledge, this paper explores the influence of distinct design variables (i.e. the porous filter, the pressure transducer, the water reservoir size and the protective casing) on the measuring range of HCTs. Seven prototypes were manufactured with different combinations of the above design variables showing that, if HCTs are properly saturated, the air entry value of the filter has the strongest influence on the measuring range whileAbstract: The High Capacity Tensiometer (HCT) is a soil sensor that can measure large negative pore-water pressures, i.e. in excess of −1 MPa, and is a key instrument for monitoring ground-atmosphere interactions. The design of HCTs has not changed since the first prototype was proposed in the 1990s and still includes three main components, namely a high air-entry value porous filter, a small water reservoir and a pressure transducer, which are all encased inside a protective sheath. Despite many successful examples of measurement of pore-water tension in the laboratory and the field, there are essentially no commercially available HCTs for industrial applications. The rare utilization of HCTs in engineering practice has always relied on bespoke devices that have been purposely designed by research laboratories or suppliers of soil sensors. The dissemination of HCTs into engineering practice has been further hindered by the relatively poor understanding of sensor design and its impact on the reliability of measurements. To overcome such gap of knowledge, this paper explores the influence of distinct design variables (i.e. the porous filter, the pressure transducer, the water reservoir size and the protective casing) on the measuring range of HCTs. Seven prototypes were manufactured with different combinations of the above design variables showing that, if HCTs are properly saturated, the air entry value of the filter has the strongest influence on the measuring range while the effects of reservoir size, pressure transducer and protective casing are relatively modest. It is expected that the results from this work will guide future design of HCTs, thus contributing to the development of resilient sensors for geotechnical applications. Highlights: The suction measuring range of seven distinct high capacity tensiometer prototypes has been compared. Larger air entry value of the porous filter increases the suction measurement range. The air entry value is inversely related to the size of largest pore in the porous filter. Water reservoir size and protective casing have little influence on the suction range. The application of larger water pressures during saturation increases the suction range. … (more)
- Is Part Of:
- Physics and chemistry of the earth. Volume 120(2020)
- Journal:
- Physics and chemistry of the earth
- Issue:
- Volume 120(2020)
- Issue Display:
- Volume 120, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 120
- Issue:
- 2020
- Issue Sort Value:
- 2020-0120-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- High capacity tensiometers -- Pore-water tension -- Soil suction
Geophysics -- Periodicals
Geochemistry -- Periodicals
Earth sciences -- Periodicals
Geodesy -- Periodicals
Astrophysics -- Periodicals
550 - Journal URLs:
- http://www.elsevier.com/journals ↗
- DOI:
- 10.1016/j.pce.2020.102901 ↗
- Languages:
- English
- ISSNs:
- 1474-7065
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6478.040000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15335.xml