Unbalanced currents of EHV multi-circuit lines and coordination of zero-sequence overcurrent relayings. (March 2021)
- Record Type:
- Journal Article
- Title:
- Unbalanced currents of EHV multi-circuit lines and coordination of zero-sequence overcurrent relayings. (March 2021)
- Main Title:
- Unbalanced currents of EHV multi-circuit lines and coordination of zero-sequence overcurrent relayings
- Authors:
- Li, Bin
Wang, Wenbo
Wen, Weijie
Yao, Bin
He, Jiawei
Wang, Xingguo - Abstract:
- Highlights: A lateral coordination scheme for zero-sequence overcurrent relaying is proposed. The mechanism and influence factors of unbalanced current are researched. The impact of ground faults on unbalanced current of adjacent circuit is analyzed. Abstract: With features of large transmission capability and high utilization efficiency of transmission corridor, multi-circuit transmission lines sharing tower or corridor are widely applied in extremely high voltage (EHV) systems. However, mal-operation of zero-sequence overcurrent relaying for multi-circuit transmission lines could occur, and this paper is focused to solve this problem. Overview of typical multi-circuits transmission lines, including phase arrangement and erection form, are introduced first. Then, simulation model of a typical 500 kV triple-circuit transmission line in real project is established in Power Systems Computer Aided Design (PSCAD), and it is verified by real record data provided by power utility in China. By using this simulation model, factors on current unbalances are discussed in detail, and the simulation results have shown that mal-operation of zero-sequence overcurrent relaying is caused by large unbalanced current in normal operation and under faults. Consequently, a lateral coordination scheme for zero-sequence overcurrent relayings among multi-circuit lines is proposed to avoid the mal-operation caused by unbalanced current to the greatest extent without receiving samples from remote endHighlights: A lateral coordination scheme for zero-sequence overcurrent relaying is proposed. The mechanism and influence factors of unbalanced current are researched. The impact of ground faults on unbalanced current of adjacent circuit is analyzed. Abstract: With features of large transmission capability and high utilization efficiency of transmission corridor, multi-circuit transmission lines sharing tower or corridor are widely applied in extremely high voltage (EHV) systems. However, mal-operation of zero-sequence overcurrent relaying for multi-circuit transmission lines could occur, and this paper is focused to solve this problem. Overview of typical multi-circuits transmission lines, including phase arrangement and erection form, are introduced first. Then, simulation model of a typical 500 kV triple-circuit transmission line in real project is established in Power Systems Computer Aided Design (PSCAD), and it is verified by real record data provided by power utility in China. By using this simulation model, factors on current unbalances are discussed in detail, and the simulation results have shown that mal-operation of zero-sequence overcurrent relaying is caused by large unbalanced current in normal operation and under faults. Consequently, a lateral coordination scheme for zero-sequence overcurrent relayings among multi-circuit lines is proposed to avoid the mal-operation caused by unbalanced current to the greatest extent without receiving samples from remote end or adjacent circuits, and the reliability of protective relaying is improved significantly. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 126(2021)Part A
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 126(2021)Part A
- Issue Display:
- Volume 126, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 126
- Issue:
- 1
- Issue Sort Value:
- 2021-0126-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Multi-circuit line -- Electromagnetic coupling -- Current unbalance -- Zero-sequence overcurrent relaying -- Lateral coordination
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2020.106607 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15322.xml