Technical Validity of a Customized Assay of Sensitivity to Endocrine Therapy Using Sections from Fixed Breast Cancer Tissue. (2nd July 2020)
- Record Type:
- Journal Article
- Title:
- Technical Validity of a Customized Assay of Sensitivity to Endocrine Therapy Using Sections from Fixed Breast Cancer Tissue. (2nd July 2020)
- Main Title:
- Technical Validity of a Customized Assay of Sensitivity to Endocrine Therapy Using Sections from Fixed Breast Cancer Tissue
- Authors:
- Lau, Rosanna
Du, Lili
Chen, Eveline
Fu, Chunxiao
Gould, Rebekah
Marczyk, Michal
Sinn, Bruno V
Layman, Rachel
Bedrosian, Isabelle
Valero, Vicente
Symmans, W Fraser - Abstract:
- Abstract: Background: We translated a multigene expression index to predict sensitivity to endocrine therapy for Stage II–III breast cancer (SET2, 3) to hybridization-based expression assays of formalin-fixed paraffin-embedded (FFPE) tissue sections. Here we report the technical validity with FFPE samples, including preanalytical and analytical performance. Methods: We calibrated SET2, 3 from microarrays (Affymetrix U133A) of frozen samples to hybridization-based assays of FFPE tissue, using bead-based QuantiGene Plex (QGP) and slide-based NanoString (NS). The following preanalytical and analytical conditions were tested in controlled studies: replicates within and between frozen and fixed samples, age of paraffin blocks, homogenization of fixed sections versus extracted RNA, core biopsy versus surgically resected tumor, technical replicates, precision over 20 weeks, limiting dilution, linear range, and analytical sensitivity. Lin's concordance correlation coefficient (CCC) was used to measure concordance between measurements. Results: SET2, 3 index was calibrated to use with QGP (CCC 0.94) and NS (CCC 0.93) technical platforms, and was validated in two cohorts of older fixed samples using QGP (CCC 0.72, 0.85) and NS (CCC 0.78, 0.78). QGP assay was concordant using direct homogenization of fixed sections versus purified RNA (CCC 0.97) and between core and surgical sample types (CCC 0.90), with 100% accuracy in technical replicates, 1–9% coefficient of variation over 20Abstract: Background: We translated a multigene expression index to predict sensitivity to endocrine therapy for Stage II–III breast cancer (SET2, 3) to hybridization-based expression assays of formalin-fixed paraffin-embedded (FFPE) tissue sections. Here we report the technical validity with FFPE samples, including preanalytical and analytical performance. Methods: We calibrated SET2, 3 from microarrays (Affymetrix U133A) of frozen samples to hybridization-based assays of FFPE tissue, using bead-based QuantiGene Plex (QGP) and slide-based NanoString (NS). The following preanalytical and analytical conditions were tested in controlled studies: replicates within and between frozen and fixed samples, age of paraffin blocks, homogenization of fixed sections versus extracted RNA, core biopsy versus surgically resected tumor, technical replicates, precision over 20 weeks, limiting dilution, linear range, and analytical sensitivity. Lin's concordance correlation coefficient (CCC) was used to measure concordance between measurements. Results: SET2, 3 index was calibrated to use with QGP (CCC 0.94) and NS (CCC 0.93) technical platforms, and was validated in two cohorts of older fixed samples using QGP (CCC 0.72, 0.85) and NS (CCC 0.78, 0.78). QGP assay was concordant using direct homogenization of fixed sections versus purified RNA (CCC 0.97) and between core and surgical sample types (CCC 0.90), with 100% accuracy in technical replicates, 1–9% coefficient of variation over 20 weekly tests, linear range 3.0–11.5 (log2 counts), and analytical sensitivity ≥2.0 (log2 counts). Conclusions: Measurement of the novel SET2, 3 assay was technically valid from fixed tumor sections of biopsy or resection samples using simple, inexpensive, hybridization methods, without the need for RNA purification. … (more)
- Is Part Of:
- Clinical chemistry. Volume 66:Number 7(2020)
- Journal:
- Clinical chemistry
- Issue:
- Volume 66:Number 7(2020)
- Issue Display:
- Volume 66, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 66
- Issue:
- 7
- Issue Sort Value:
- 2020-0066-0007-0000
- Page Start:
- 934
- Page End:
- 945
- Publication Date:
- 2020-07-02
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1093/clinchem/hvaa105 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15310.xml