The EuBIVAS: Within- and Between-Subject Biological Variation Data for Electrolytes, Lipids, Urea, Uric Acid, Total Protein, Total Bilirubin, Direct Bilirubin, and Glucose. (1st September 2018)
- Record Type:
- Journal Article
- Title:
- The EuBIVAS: Within- and Between-Subject Biological Variation Data for Electrolytes, Lipids, Urea, Uric Acid, Total Protein, Total Bilirubin, Direct Bilirubin, and Glucose. (1st September 2018)
- Main Title:
- The EuBIVAS: Within- and Between-Subject Biological Variation Data for Electrolytes, Lipids, Urea, Uric Acid, Total Protein, Total Bilirubin, Direct Bilirubin, and Glucose
- Authors:
- Aarsand, Aasne K
Díaz-Garzón, Jorge
Fernandez-Calle, Pilar
Guerra, Elena
Locatelli, Massimo
Bartlett, William A
Sandberg, Sverre
Røraas, Thomas
Ceriotti, Ferruccio
Sølvik, Una Ørvim
Sverresdotter Sylte, Marit
Coşkun, Abdurrahman
Serteser, Mustafa
Unsal, Ibrahim
Tosato, Francesca
Plebani, Mario
Jonker, Niels
Barla, Gerhard
Carobene, Anna - Abstract:
- Abstract: BACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine European Biological Variation Study (EuBIVAS) has been established to deliver rigorously determined data describing biological variation (BV) of clinically important measurands. Here, EuBIVAS-based BV estimates of serum electrolytes, lipids, urea, uric acid, total protein, total bilirubin, direct bilirubin, and glucose, as well as their associated analytical performance specifications (APSs), are presented. METHOD: Samples were drawn from 91 healthy individuals (38 male, 53 female; age range, 21–69 years) for 10 consecutive weeks at 6 European laboratories. Samples were stored at −80 °C before duplicate analysis of all samples on an ADVIA 2400 (Siemens Healthineers). Outlier and homogeneity analyses were performed, followed by CV-ANOVA on trend-corrected data, when relevant, to determine BV estimates with CIs. RESULTS: The within-subject BV (CVI ) estimates of all measurands, except for urea and LDL cholesterol, were lower than estimates available in an online BV database, with differences being most pronounced for HDL cholesterol, glucose, and direct bilirubin. Significant differences in CVI for men and women/women <50 years of age were evident for uric acid, triglycerides, and urea. The CVA obtained for sodium and magnesium exceeded the EuBIVAS-based APS for imprecision. CONCLUSIONS: The EuBIVAS, which is fully compliant with the recently published Biological Variation Data CriticalAbstract: BACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine European Biological Variation Study (EuBIVAS) has been established to deliver rigorously determined data describing biological variation (BV) of clinically important measurands. Here, EuBIVAS-based BV estimates of serum electrolytes, lipids, urea, uric acid, total protein, total bilirubin, direct bilirubin, and glucose, as well as their associated analytical performance specifications (APSs), are presented. METHOD: Samples were drawn from 91 healthy individuals (38 male, 53 female; age range, 21–69 years) for 10 consecutive weeks at 6 European laboratories. Samples were stored at −80 °C before duplicate analysis of all samples on an ADVIA 2400 (Siemens Healthineers). Outlier and homogeneity analyses were performed, followed by CV-ANOVA on trend-corrected data, when relevant, to determine BV estimates with CIs. RESULTS: The within-subject BV (CVI ) estimates of all measurands, except for urea and LDL cholesterol, were lower than estimates available in an online BV database, with differences being most pronounced for HDL cholesterol, glucose, and direct bilirubin. Significant differences in CVI for men and women/women <50 years of age were evident for uric acid, triglycerides, and urea. The CVA obtained for sodium and magnesium exceeded the EuBIVAS-based APS for imprecision. CONCLUSIONS: The EuBIVAS, which is fully compliant with the recently published Biological Variation Data Critical Appraisal Checklist, has produced well-characterized, high-quality BV estimates utilizing a stringent experimental protocol. These new reference data deliver revised and more exacting APS and reference change values for commonly used clinically important measurands, thus having direct relevance to diagnostics manufacturers, service providers, clinical users, and ultimately patients. … (more)
- Is Part Of:
- Clinical chemistry. Volume 64:Number 9(2018)
- Journal:
- Clinical chemistry
- Issue:
- Volume 64:Number 9(2018)
- Issue Display:
- Volume 64, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 64
- Issue:
- 9
- Issue Sort Value:
- 2018-0064-0009-0000
- Page Start:
- 1380
- Page End:
- 1393
- Publication Date:
- 2018-09-01
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1373/clinchem.2018.288415 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15309.xml