Sandwich Immunoassay for Bioactive Plasma Adrenomedullin. (15th October 2019)
- Record Type:
- Journal Article
- Title:
- Sandwich Immunoassay for Bioactive Plasma Adrenomedullin. (15th October 2019)
- Main Title:
- Sandwich Immunoassay for Bioactive Plasma Adrenomedullin
- Authors:
- Weber, Julia
Sachse, Janine
Bergmann, Sarah
Sparwaßer, Andrea
Struck, Joachim
Bergmann, Andreas - Abstract:
- Abstract: Background: Adrenomedullin (ADM) is a circulating peptide known to regulate vasodilation and vascular integrity. Increased plasma ADM concentrations have been described for several life-threatening conditions, including cardiovascular diseases and septic shock. Reliable methods for the simple quantification of bioactive ADM (bio-ADM) are lacking. Methods: Monoclonal antibodies against the amidated C-terminus and middle portion of bio-ADM were generated and used for the development of a 1-step immunometric assay for the specific quantification of bio-ADM in plasma. The assay was developed in a microtiter plate/chemiluminescence label format with a significantly reduced incubation time. Precision, linearity, specimen stability, and distribution of results in healthy subjects were evaluated. Results: The use of monoclonal antibodies against predetermined epitopes of bio-ADM enabled the development of an assay for the determination of bio-ADM directly in EDTA plasma. Plasma samples were stable for up to 24 h at ambient temperature and over multiple freeze–thaw cycles without loss of immunoreactivity. The assay had a limit of detection of 3 pg/mL and a limit of quantification of 11 pg/mL. The assay exhibited acceptable linearity characteristics and was not influenced by complement factor H, a putative ADM-binding protein. In healthy subjects, bio-ADM concentrations were all above the limit of detection, and approximately half of them were above the limit ofAbstract: Background: Adrenomedullin (ADM) is a circulating peptide known to regulate vasodilation and vascular integrity. Increased plasma ADM concentrations have been described for several life-threatening conditions, including cardiovascular diseases and septic shock. Reliable methods for the simple quantification of bioactive ADM (bio-ADM) are lacking. Methods: Monoclonal antibodies against the amidated C-terminus and middle portion of bio-ADM were generated and used for the development of a 1-step immunometric assay for the specific quantification of bio-ADM in plasma. The assay was developed in a microtiter plate/chemiluminescence label format with a significantly reduced incubation time. Precision, linearity, specimen stability, and distribution of results in healthy subjects were evaluated. Results: The use of monoclonal antibodies against predetermined epitopes of bio-ADM enabled the development of an assay for the determination of bio-ADM directly in EDTA plasma. Plasma samples were stable for up to 24 h at ambient temperature and over multiple freeze–thaw cycles without loss of immunoreactivity. The assay had a limit of detection of 3 pg/mL and a limit of quantification of 11 pg/mL. The assay exhibited acceptable linearity characteristics and was not influenced by complement factor H, a putative ADM-binding protein. In healthy subjects, bio-ADM concentrations were all above the limit of detection, and approximately half of them were above the limit of quantification. Conclusions: By using monoclonal antibodies with defined epitope specificities, we have developed a simple, rapid, accurate, and sensitive sandwich immunoassay for bio-ADM. The assay is a potentially novel tool to support patient management, particularly in acute care in the field of sepsis and other indications, which are currently being investigated, such as acute heart failure. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 2:Number 2(2017)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 2:Number 2(2017)
- Issue Display:
- Volume 2, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 2
- Issue:
- 2
- Issue Sort Value:
- 2017-0002-0002-0000
- Page Start:
- 222
- Page End:
- 233
- Publication Date:
- 2019-10-15
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1373/jalm.2017.023655 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15309.xml