Endovascular aortic repair with the Gore Excluder Conformable endograft in severe neck angulation: Preliminary experience and technical aspects. (April 2021)
- Record Type:
- Journal Article
- Title:
- Endovascular aortic repair with the Gore Excluder Conformable endograft in severe neck angulation: Preliminary experience and technical aspects. (April 2021)
- Main Title:
- Endovascular aortic repair with the Gore Excluder Conformable endograft in severe neck angulation: Preliminary experience and technical aspects
- Authors:
- Bonvini, Stefano
Tasselli, Sebastiano
Raunig, Igor
Wassermann, Valentina
Piazza, Michele
Antonello, Michele - Abstract:
- Objectives: Endovascular procedures are now the standard of care for endovascular aortic aneurysm repair but treatment of hostile proximal neck anatomy is still challenging. New endografts were brought to the market specifically designed to accommodate severe neck angulation. Authors describe a preliminary experience and early results using the Gore Excluder Conformable endograft (W. L. Gore & Associates, Flagstaff, Ariz) and its active control system in severe neck angulation with a standardized technical approach to achieve precise deployment in this hostile anatomy. Methods: From June 2019 to May 2020, five patients with abdominal aortic aneurysm and severe neck angulation (≥70°) were treated with the Gore Excluder Conformable endograft at two different centers. Deployment of this endograft in this kind of anatomy should be aggressive starting over the level of renal arteries due to risk of distal migration downward on the external curvature and difficulty in upward repositioning. Authors suggested a standard technique with a routine through-and-through axillary–femoral approach, using a floppy guidewire together with preventive cannulation of the lower renal artery if a short neck (<15 mm) is associated. Results: Endovascular aortic procedures were successfully completed in all patients. Final deployment of the stent graft using our standardized technical approach was extremely precise in all cases even if redeployment of the graft was necessary in all cases. No otherObjectives: Endovascular procedures are now the standard of care for endovascular aortic aneurysm repair but treatment of hostile proximal neck anatomy is still challenging. New endografts were brought to the market specifically designed to accommodate severe neck angulation. Authors describe a preliminary experience and early results using the Gore Excluder Conformable endograft (W. L. Gore & Associates, Flagstaff, Ariz) and its active control system in severe neck angulation with a standardized technical approach to achieve precise deployment in this hostile anatomy. Methods: From June 2019 to May 2020, five patients with abdominal aortic aneurysm and severe neck angulation (≥70°) were treated with the Gore Excluder Conformable endograft at two different centers. Deployment of this endograft in this kind of anatomy should be aggressive starting over the level of renal arteries due to risk of distal migration downward on the external curvature and difficulty in upward repositioning. Authors suggested a standard technique with a routine through-and-through axillary–femoral approach, using a floppy guidewire together with preventive cannulation of the lower renal artery if a short neck (<15 mm) is associated. Results: Endovascular aortic procedures were successfully completed in all patients. Final deployment of the stent graft using our standardized technical approach was extremely precise in all cases even if redeployment of the graft was necessary in all cases. No other secondary procedures were needed. At 30 days, no type IA endoleak was recorded and no aneurysm-related secondary procedures were performed. Median follow-up for this group of patients was 5.2 months (range 1–11). Early results revealed no type IA endoleak and no migration at Ct angiogram. No aneurysm-related secondary procedures were required. Conclusion: Routine use of through-and-through axillary–femoral guidewire associated with selective pre-cannulation of the lower renal artery allows a precise deployment of the Gore Excluder Conformable endograft in difficult anatomies possibly affecting early outcomes. … (more)
- Is Part Of:
- Vascular. Volume 29:Number 2(2021)
- Journal:
- Vascular
- Issue:
- Volume 29:Number 2(2021)
- Issue Display:
- Volume 29, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2021-0029-0002-0000
- Page Start:
- 183
- Page End:
- 189
- Publication Date:
- 2021-04
- Subjects:
- Abdominal aortic aneurysm -- endovascular aortic repair -- Gore Excluder Conformable stentgraft -- severe neck angulation -- deployment technique -- endoleak
616.13 - Journal URLs:
- http://vascular.rsmjournals.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1708538120952665 ↗
- Languages:
- English
- ISSNs:
- 1708-5381
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15309.xml